Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0626-00969
Parcel: 115180220

Address:
1475 N ORACLE RD

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0626-00969
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/30/2026 Commercial Electrical Express REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please revise the plans to demonstrate that the floor penetration fire-stop system protected in accordance with the IBC section 714.5.1.1.
Provide detail drawings and references on the plans identifying the specific tested and listed firestopping systems (UL, Intertek, or other approved equivalent) proposed for each condition. Details shall identify the applicable listing number and demonstrate compatibility with the construction type, hourly rating, penetrating item, annular space, and required fire-resistance rating. Typical systems may include, as applicable, firestop sealants, intumescent materials, fire-stop collars, sleeves, wrap strips, and cast-in devices.
Please provide a fire stop system for this floor penetration with a minimum of a 2-hour rating.
2024 IBC Section 714.5.1.1,
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
06/29/2026 PDSD Application Completeness Express REVIEW COMPLETED