Permit Number: TC-COM-0626-00940
Parcel: 13408277K

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.3

Permit Number - TC-COM-0626-00940
Review Name: COMMERCIAL REVIEW - LIMITED v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2026 Site Zoning APPROVED
07/10/2026 Site Engineering NOT REQUIRED
07/21/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/06/2026 Addressing Validation REQUIRES RESUBMIT If you have questions regarding this review, please contact CDRC@tucsonaz.gov.

Please include the full property address on all construction plan documents and resubmit after other reviews are complete.
07/20/2026 Commercial Building REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0626-00940
ADDRESS/PARCEL: (8383 E 22ND ST Unit: UNIT 103 TUCSON, AZ 85710)
Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed.

Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976.

COMMENTS:
A response to your submitted memo.
A set of drawings must be submitted in order for a Certificate of Occupancy to be issued. The city hears your point of view and therefore, we will require an As-Built set of drawings but still require the following to be included. All of the following will be necessary in order to review/approve your application. Some of these information will be required into generating the information that will go into the Certificate of Occupancy document. I will do my best to simplify it as much as possible.
1. Please provide a code analysis per IBC 107 which will include:
a. Code Year / Type (Building, Electrical, Fire, Mechanical, Plumbing, Energy, Existing Building, Accessibility, Outdoor Lighting Code, Local Amendments, etc.)
b. The following are the codes that this jurisdiction adopted that are available on the city website (please select the applicable codes for your project and enumerate them onto your first sheet):
i. 2018 International Energy Conservation Code (effective until 6/30/26)
ii. 2024 International Building Code (effective 1/1/26)
iii. 2024 International Existing Building Code (effective 1/1/26)
iv. 2024 International Fuel Gas Code (effective 1/1/26)
v. 2024 International Mechanical Code (effective 1/1/26)
vi. 2024 International Plumbing Code (effective 1/1/26)
vii. 2023 National Electric Code (effective 1/1/26)
viii. 2024 International Fire Code
ix. ICC A117.1 - 2017 Accessible and Usable Building and Facilities (effective 1/1/26)
c. Occupancy Classification IBC Chapter 3. Provide the occupancies that you will be using.
d. Fire Sprinklers Yes / No ________________ If Yes: New____ Existing____ Type NFPA__________ IBC 903, 903.3
e. Fire Alarm Yes / No _________________ If Yes: New____ Existing____ IBC 907
f. Area Allowable _______________ Actual Area_______________ IBC 503, 505 through 507 & Table 506.2 1.
g. Number of Exits Required ____________ (If (2) or more exits required; Egress Plan Required) Provided ____________ IBC 1006, 1007, & Tables 1006.2.1, 1006.3.3, 1006.3.4(1), 1006.3.4(2)
h. Provide an Egress Plan.
i. Enter the distance of travel within the facility and their direction of travel.
ii. At the point of exit, enter the required width, the provided width, the distance traveled and the number of occupants exiting.
i. Required Plumbing Fixtures (Provide calculations for the number of water closets, urinals, lavatories, drinking fountains, and service sinks) IBC 2902 & Table 2902.1
j. Show the current design occupant load analysis to provide the number of people who will be occupying the establishment per IBC Table 1004. IBC 107.2.7. Show the current design occupant load analysis to specify the individual building area of each room or space that is shown on the plan. For the purpose of occupant load calculation, the actual use of the space shall be utilized. Further, enter the name of the space, area square footage, clarify the design occupant load (gross or net s.f. per person used) and the number of occupants for each room or space on the plan, in accordance with the requirements of IBC Table 1004. IBC 107.2.7

2. Ensure that the facility is accessible complying to the ICC/ANSI A117.1 for both Employees and Customers. The tops of dining surfaces and work surfaces 902.4: shall be 28 inches min and 34 inches max above the floor. Parallel approach 904.3.2: the public use side of the counter surface 36 inches in length minimum. Forward approach 904.3.3: the public use side of the counter surface 30 inches minimum in length. Knee clearance 306.3: between 9 inches and 27 inches above the floor. Maximum depth 306.3.2: extend 25 inches maximum under an element at 9 inches above the floor. Minimum depth 06.3.3: Where clear floor space complying with Section 305, the knee clearance shall be 11 inches minimum in depth at 9 inches above the floor, and 8 inches minimum in depth at 27 inches above the floor.
3. Per the State of Arizona Board of Technical Registration Arizona Administrative Code R4-30-303 and R4-30-304 before sealing any work, Registrant shall secure and use a seal for a branch in which registration has been granted. A permanently legible imprint of the registrant’s seal, signature, date signed shall appear on all drawings generated and must bear the branch phrase applicable to the registrant such as Architectural/Structural/Civil/Electrical/Fire Protection/Mechanical/Land Surveyor, etc.
4. As stated above, an Arizona licensed Architect is required to generate all of the above.
5. The following drawings shall be required.
a. Architectural
b. Mechanical
c. Electrical
d. Plumbing
7. Please resubmit.
07/14/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0626-00940 (8383 E 22ND ST Unit:UNIT 103 TUCSON, AZ 85710)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov


1. According to the 2023 National Electrical Code (NEC) Article 517, facilities offering medical aesthetics and cosmetic injectable services (like Botox) are considered Health Care Facilities.
2. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf
3. Provide electrical plans for the reclassified space, which provides health care services to humans. This space, due to the new occupancy classification, shall meet the requirements of NEC 517, and existing electoral must be shown to already meet these requirements, or be updated appropriately.
07/20/2026 Commercial Mechanical REQUIRES RESUBMIT To obtain a certificate of occupancy for a space (i.e., Suite 103), an architect or an engineer registered in the State of Arizona must submit the following documents:
• A complete code analysis for the space
• A complete site plan
• A complete floor plan
• A complete egress plan
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov
07/20/2026 Commercial Plumbing REQUIRES RESUBMIT To obtain a certificate of occupancy for a space (i.e., Suite 103), an architect or an engineer registered in the State of Arizona must submit the following documents:
• A complete code analysis for the space
• A complete site plan
• A complete floor plan
• A complete egress plan
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
07/21/2026 Fire New Construction REQUIRES RESUBMIT Please provide all required documents for a review.
john.vincent@tucsonaz.gov
5203495581
07/20/2026 Water - PDSD REQUIRES RESUBMIT Show the location and size of the water meter, backflow preventer, and the water service pipe on a site plan. Reference: Section 107.2.1 and 107.2.6, IBC 2024.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov
07/06/2026 PDSD Application Completeness Express REVIEW COMPLETED