Permit Number: TC-COM-0626-00939
Parcel: 107111170

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0626-00939
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2026 Commercial Building APPROVED
07/09/2026 Commercial Mechanical APPROVED
07/09/2026 Water - PDSD APPROVED
06/26/2026 Site Engineering NOT REQUIRED
07/09/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/08/2026 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0626-00939 (201 W FORT LOWELL RD TUCSON, AZ 85705)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide GFCI protection, per NEC 210.8(D)(2), for the new water dispenser. Show the circuit number.
2. Provide GFCI protection, or verify existing GFCI protection, for the receptacle within the exiting Utility room and within 6 feet of the utility sink, NEC 210.8(B).
3. Show the wiring method for the conductors under the new power-cord accessible ramp. An extension cord cannot be used as a permanent wiring method to provide power from the wall receptacle to the Point of Sale (POS). Is the power-cord accessible ramp listed for this use?
07/09/2026 Commercial Plumbing REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0626-00939
ADDRESS/PARCEL: 201 W FORT LOWELL RD TUCSON, AZ 85705)

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please clarify the type of water dispenser being provided and provide the manufacturer’s installation instructions. Based on the type of dispenser, a waste connection may be required. Reference: Section 107.2.1, IBC 2024.
2. Also, the plans indicate signage stating “No Public Admittance” at the door leading to the area containing the water dispenser. Please clarify why it is located in an area not accessible to the public. Revise the plans or provide clarification as necessary. Reference: Section 107.2.1, IBC 2024.
07/07/2026 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0626-00939
201 W. Fort Lowell Rd. Tucson, AZ 85705
CofO for Smoke Shop (1st Review)

TRANSMITTAL DATE: 7/7/2026

The site is located in C-2 zone (UDC 4.7.21). Smoke Shop is a permitted use in this zone subject to Use Specific Standard 4.9.9.H (UDC Table 4.8-4).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Google Streetview shows a fence was erected sometime around 2020 however Site Zoning is unable to find permits associated with this fence. Please provide the approved permit number for this perimeter fence. If there is no associated fence permit, a fence permit and a minor Development Package will be required since W. Fort Lowell is considered a collector street. Site zoning is unable to approve this permit until either an approved fence permit number has been provided or a Development Package and fence permit have been applied for.
2. Comment: The provided site plan shows access and parking originating from the parcel to the West (Parcel 107111180). Please include a signed and notarized Covenant Regarding Development and Use of Real Property to formalize this shared use or provide an approved lot combination form from Pima County: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/submission-documents/covenant-regarding-development-and-use-of-real-property-udc-with-release.pdf
https://www.asr.pima.gov/Downloads/Forms/ComboRequest.pdf
Either of these documents can be provided in the Development Package if a fence permit was not previously applied for.
3. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
06/25/2026 Fire New Construction REVIEW COMPLETED
06/24/2026 PDSD Application Completeness Express REVIEW COMPLETED