| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/15/2026 | Commercial Plumbing Standard | APPROVED | |||
| 07/13/2026 | Site Zoning Standard | APPROVED | |||
| 07/15/2026 | Water - PDSD Standard | APPROVED | |||
| 07/02/2026 | Design Review Standard | NOT REQUIRED | Not in a Special District. | ||
| 07/15/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 07/15/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 07/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/15/2026 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0626-00932 ADDRESS/PARCEL: (5950 E BROADWAY BL Unit:UNIT 140 TUCSON, AZ 85711) TC-COM-0526-00787 (3002 E GRANT RD Unit:UNIT 2 TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Should you have any questions about these Commercial Building comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976. COMMENTS: 1. SHEET T000 PROJECT DATA a. Restaurant proposed Use b. II-B Construction Type (NO mention on fire sprinkler and or alarm) PLEASE SPECIFY c. A-2 Occupancy Group 2. SHEET A100 2024 INTERNATIONAL BUILDING CODE MATRIX a. Business b. V-B Construction Type (SPRINKLERED) c. B Occupancy Classification d. ******NOTE: Please correct the discrepancy. The information within item #2 and item #1 above does no match. 3. SHEET T002 CLEAR FLOOR SPACE a. Detail B1 and B2, the clear floor space shown is 48” min (please correct to reflect 52" per ICC A117.1 Figure 305.3.1) 4. KITCHEN HOOD a. Please provide Structural Calculation and Detail Drawings for the kitchen hood and how it is attached to the structure above. b. Ensure that the Arizona Licensed Structural Engineer seal/sign/date all documents. 5. Please resubmit. |
||
| 07/15/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00932 (5950 E BROADWAY BL Unit:UNIT 140 TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide panel schedule with clear description of receptacle locations. NEC 408.4. There are multiple kitchen and other utilization equipment with the same designation. There are multiple circuits called out as 'RECEPTACLE', but not clearly which ones. 2. Designate the circuit number at the location of each light fixture, receptacle, appliance, and equipment disconnect switch, NEC [110.22(A)]. Reference sheet E100, multiple receptacles, fixtures and outlets are not clearly designated with panel/circuit. |
||
| 07/15/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0626-00932 ADDRESS/PARCEL: 5950 E BROADWAY BL Unit:UNIT 140 TUCSON, AZ 85711 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Please coordinate the values shown in the Ventilation Schedule with those shown in the Air Balance Schedule. Zone IU-5T-3 should show 560 CFM outdoor air (552 CFM) in the Air Balance Schedule, and Zone IU-5T-2 should show 200 CFM outdoor air (201 CFM). Reference: Section 107.2.1, IBC 2024. 2. On Sheet M100, please revise the keynotes to match the Ventilation Schedule. The keynote associated with IU-5T-2 should reference Note 12, indicating 200 CFM of outdoor air, and the keynote associated with IU-5T-3 should reference Note 11, indicating 560 CFM of outdoor air. Reference: Section 107.2.1, IBC 2024. |
||
| 07/15/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 06/24/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |