Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2
Permit Number - TC-COM-0626-00915
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/25/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/25/2026 | Commercial Electrical Express | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00915 (45 W FORT LOWELL RD Unit:UNIT 26 TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide main-panel rating and Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. |
||
| 08/25/2026 | Commercial Mechanical Express | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0626-00915 ADDRESS/PARCEL: 45 W FORT LOWELL RD Unit:UNIT 26 TUCSON, AZ 85705 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Please include a site plan showing the unit location on the site and the location of the equipment. Reference: Section 107.2.1, IBC 2024. 2. The plans identify the mini-split as existing. Please clarify whether the Hessaire H12HP1A-15 is an existing unit or a new replacement unit. Reference: Section 107.2.1, IBC 2024. 3. Previous comment not addressed [Initial comment – Provide heating and cooling load calculations to justify the heating/cooling capacity of the unit. Reference: Section C403.1.1 and C502.2.3, IECC 2018.] a. Please provide heating and cooling load calculations (also known as Manual J calculations or HVAC sizing calculations) |
||
| 08/25/2026 | Addressing Validation | REVIEW COMPLETED |