Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0626-00895
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/12/2026 | Commercial Building Standard | APPROVED | |||
| 07/13/2026 | Commercial Mechanical Standard | APPROVED | |||
| 07/13/2026 | Commercial Plumbing Standard | APPROVED | |||
| 07/09/2026 | Site Zoning Standard | APPROVED | Ref: TZ-CMP-0526-00088 | ||
| 07/13/2026 | Water - PDSD Standard | APPROVED | |||
| 06/18/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 07/13/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/09/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00895 (1634 N OLSEN AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. The provided Fault Current Analysis shows the short circuit at panel ‘A’ at 12,641A, but the AIC rating for panel ‘A’ is only shown at 10,000A. Provide a panel with an AIC rating sufficient to withstand the calculated Fault Current. 2023 NEC 110.24, NEC 110.9, 110.10, 240.86. 2. Provided GFCI protection for all new and existing receptacles within the new Men’s and Women’s Locker rooms, NEC 210.8(B)(9). 3. Provide the correct circuit designation for a (N) receptacle in the bathroom just off the Vestibule, room 127. Also needs to be show as GFCI protected. NEC 210.8(B)(1). circuit designation currently shows ‘C’-XX. EF-3 is in this same bathroom for reference. 4. Show the existing receptacles withing the Lounge 01, 125, with GFCI protection with the new Jacuzzi/cold plunge. NEC 210.8(B)(8) 5. Multiple receptacles are marked with the incorrect abbreviation, GRCI. Correct and show as GFCI protected. 6. Clarify if the lighting fixtures labeled with ‘LT*’ are existing or new. Are they just being recircuited per the Keyed Notes on sheet E3.0? |
||
| 07/09/2026 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0626-00895 (1634 N OLSEN AV TUCSON, AZ 85719) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Clarify if there are changes to the outdoor lighting. Specifically if LT-11 is new lighting fixtures. Compliance with the outdoor lighting will be required for any new or modified outdoor lighting. |
||
| 06/22/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 06/18/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |