Permit Review Detail
Review Status: In Review
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0626-00870
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2026 | Commercial Building | APPROVED | |||
| 06/18/2026 | Site Engineering | NOT REQUIRED | |||
| N/A | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| N/A | Commercial Mechanical | PENDING ASSIGNMENT | |||
| N/A | Commercial Plumbing | PENDING ASSIGNMENT | |||
| N/A | Site Zoning | PENDING ASSIGNMENT | |||
| N/A | Water - PDSD | PENDING ASSIGNMENT | |||
| 06/23/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00870 (1710 W VALENCIA RD Unit:UNIT 120 TUCSON, AZ 85746) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide a complete set of electrical drawing for the scope of work being done. Plans shall include (as necessary for scope of work), but may not be limited to items below: 2. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. Make clear which circuits are being used for new equipment and which are being remaining the same. 3. Provide a panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. highlight the modified, or new circuits. 4. Provide an electrical plan and Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. 5. Show GFCI protection for any new, modified or reused circuits within the kitchen, NEC 210.8(B) & (D). |
||
| 06/21/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 06/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |