Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0626-00855
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2026 | Commercial Building | APPROVED | |||
| 06/18/2026 | Site Engineering | APPROVED | |||
| 06/26/2026 | Site Zoning | APPROVED | Associated DP (TD-DEV-0226-00049) has been approved. | ||
| 06/26/2026 | Commercial Mechanical | NOT REQUIRED | No mechanical/plumbing work or modifications | ||
| 06/26/2026 | Commercial Plumbing | NOT REQUIRED | No mechanical/plumbing work or modifications | ||
| 06/26/2026 | Water - PDSD | NOT REQUIRED | |||
| 06/29/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/18/2026 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0626-00855 (1435 W SAINT MARYS RD TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide electrical plan sheets as noted in the structural sheet key notes. 2. Show electrical circuits that are being modified or relocated or changed. 3. Show lighting fixtures as full cutoff per the Outdoor Lighting Code definition of fully cutoff, and with a maximum color temperature of 3500K. 4. Provide a Grounding Electrode System at the detached structure per 250.31(A). Grounding electrode system and grounding electrode conductor. Required. 5. Provide for local disconnecting means at the structure for the canopy lighting as required per NEC art 225.31-32. 250.31(A) Grounding electrode system and grounding electrode conductor. Required. 250.31(B) equipment grounding conductor, grounding bonding equipment and structural metal. Sized accordance with 250.122. 250.32(D), disconnecting means located in separate building or structure. See also 225.31(B) exception No. 1. |
||
| 06/21/2026 | Fire New Construction | REVIEW COMPLETED | |||
| 06/12/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |