Permit Number: TC-COM-0626-00795
Parcel: 112062320

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0626-00795
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2026 Commercial Mechanical Standard APPROVED
06/25/2026 Site Zoning Standard APPROVED Site Zoning approval is for demising walls interior shell TI ONLY. A separate CofO permit will be required for each newly created unit.
06/25/2026 Water - PDSD Standard APPROVED
06/12/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
06/12/2026 Site Engineering Standard NOT REQUIRED
06/25/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please revise the plans to show the accessible route from the accessible parking stall(s) to the accessible entry doors. IBC Section 1104
2. Please revise the plans to label the accessible exits and if all exits are not accessible, provide signage per IBC section 1112.1
3. Please provide the construction valuation for the work being performed within each tenant space. The current submittal indicates a valuation of $21,000.00 for each space; however, additional detail is required to verify the accuracy of the reported valuation.
Please provide the total cost of the work being proposed (material and labor), including, but not limited to, demising walls, electrical modifications, HVAC work, plumbing, finishes, and any other construction activities proposed within each tenant space. Please provide a separate amount for each new tenant space.
TC-COM-0626-00795 -2524 N Campbell AV
4. Please revise the General Building Summary to accurately identify Suite 2524 as an A-3 Occupancy in accordance with IBC Section 303.4. Based on this occupancy classification, provide code-compliant egress features, including panic hardware on the required exit doors and illuminated exit signs at both exit doors. Please update the plans and applicable code analysis to demonstrate compliance with IBC Sections 1010.1.10, 1013.1, and 1013.3.
5. Please revise the plans to show that all through-penetrations, membrane penetrations and joints of fire-resistance-rated assemblies are protected with approved firestopping systems. Provide detail drawings on the plans identifying the specific UL-listed (or equivalent) firestopping systems for pipe, conduit, and duct penetrations through rated walls, floors, and ceilings (e.g., putty pads, firestop sealants, collars, or sleeves, as applicable). IBC Sections 714 & 715
Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
06/17/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review
TC-COM-0626-00795 (2524 N CAMPBELL AV TUCSON, AZ 85719)
TC-COM-0626-00796 (2530 N CAMPBELL AV TUCSON, AZ 85719)
TC-COM-0626-00797 (2532 N CAMPBELL AV TUCSON, AZ 85719)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov


1. Show electrical outlets, panels and other penetrations within fire-rated walls with fire ratings. IBC 714. Provide fire rating details and products used for receptacles and other electrical penetrations within the new fire rated walls. NEC Article 300.21
06/25/2026 Commercial Plumbing Standard REQUIRES RESUBMIT ACTIVITY NO.
TC-COM-0626-00795 (2524 N CAMPBELL AV TUCSON, AZ 85719)
TC-COM-0626-00796 (2530 N CAMPBELL AV TUCSON, AZ 85719)
TC-COM-0626-00797 (2532 N CAMPBELL AV TUCSON, AZ 85719)

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov

COMMENTS:

1. Please show the water supply connections for the water dispensers in Suites 2530 and 2532. Water dispensers shall be connected to a permanent supply of potable water. Reference: Section 107.2.1, IBC 2024.

See: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf
06/22/2026 Fire New Construction Standard REQUIRES RESUBMIT -Resolve all building comments.
-You show suite #2524 as an E occupancy with an OL>50. This will require a voice fire alarm per IFC 907.2.3. I suggest recalculating your OL.