Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0626-00794
Parcel: 115051270

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0626-00794
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2026 Site Zoning Standard APPROVED
07/10/2026 Site Engineering Standard NOT REQUIRED
07/20/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/20/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please provide the asbestos testing report indicating the flooring results. IBC 107.2.1
2. Sheet 2: It appears that all Wall Type W1 assemblies are proposed to be replaced. Please provide referenced plan and section details for Wall Type W1, including top and bottom connection details, fastening methods, and all associated construction materials. The details shall clearly demonstrate compliance with the proposed design. IBC Section 107.2.1.Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
07/17/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0626-00794 (110 W RILLITO ST Unit:UNIT 16 TUCSON, AZ 85705)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. NEC 240.24(D): Overcurrent protective devices shall not be located in the vicinity of easily ignitable material, such as in clothes closets.
2. Provide complete electrical plans for the scope of work being done. Note any electrical fixtures being replaced, conductor/conduits to be replace, etc.
07/14/2026 Fire New Construction Standard REVIEW COMPLETED
06/30/2026 PDSD Application Completeness Express REVIEW COMPLETED