Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0625-01285
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/25/2025 | Site Zoning Standard | APPROVED | |||
| 07/28/2025 | Water - PDSD Standard | APPROVED | |||
| 07/17/2025 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 07/09/2025 | Site Engineering Standard | NOT REQUIRED | |||
| 07/28/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/24/2025 | Commercial Building Standard | REQUIRES RESUBMIT | July 11, 2025 1st Review Intertech Architectural Interiors Attn: Maria Oldham 6089 E. Grant Road Tucson, Arizona 85712 Re: QUALITY OF LIFE MEDICAL AND RESEARCH CENTER TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0625-01285 Stantec Project Number: 185215066 Stantec File Number: TUC-25-075 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 10,950 73 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS 1. The individual space square footage and the building area square footage are conflicting. The actual building area indicates 10,500 square feet while the individual space area is indicated as 10,950 square feet. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS General 1. The electrical sheets are missing the fire riser room. Please revise the plans to include this room and the required illumination. [Ref. IBC 2018 Sec. 902.1.4] 2. Please indicate an exit sign in the area of door 101B that clearly indicates the direction of egress travel through that door. [Ref. IBC 2018 Sec.1013.1] Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 07/24/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | July 11, 2025 1st Review Intertech Architectural Interiors Attn: Maria Oldham 6089 E. Grant Road Tucson, Arizona 85712 Re: QUALITY OF LIFE MEDICAL AND RESEARCH CENTER TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0625-01285 Stantec Project Number: 185215066 Stantec File Number: TUC-25-075 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 10,950 73 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS 1. The individual space square footage and the building area square footage are conflicting. The actual building area indicates 10,500 square feet while the individual space area is indicated as 10,950 square feet. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS General 1. The electrical sheets are missing the fire riser room. Please revise the plans to include this room and the required illumination. [Ref. IBC 2018 Sec. 902.1.4] 2. Please indicate an exit sign in the area of door 101B that clearly indicates the direction of egress travel through that door. [Ref. IBC 2018 Sec.1013.1] Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 07/24/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | July 11, 2025 1st Review Intertech Architectural Interiors Attn: Maria Oldham 6089 E. Grant Road Tucson, Arizona 85712 Re: QUALITY OF LIFE MEDICAL AND RESEARCH CENTER TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0625-01285 Stantec Project Number: 185215066 Stantec File Number: TUC-25-075 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 10,950 73 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS 1. The individual space square footage and the building area square footage are conflicting. The actual building area indicates 10,500 square feet while the individual space area is indicated as 10,950 square feet. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS General 1. The electrical sheets are missing the fire riser room. Please revise the plans to include this room and the required illumination. [Ref. IBC 2018 Sec. 902.1.4] 2. Please indicate an exit sign in the area of door 101B that clearly indicates the direction of egress travel through that door. [Ref. IBC 2018 Sec.1013.1] Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 07/24/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | July 11, 2025 1st Review Intertech Architectural Interiors Attn: Maria Oldham 6089 E. Grant Road Tucson, Arizona 85712 Re: QUALITY OF LIFE MEDICAL AND RESEARCH CENTER TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0625-01285 Stantec Project Number: 185215066 Stantec File Number: TUC-25-075 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 10,950 73 Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS 1. The individual space square footage and the building area square footage are conflicting. The actual building area indicates 10,500 square feet while the individual space area is indicated as 10,950 square feet. STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS General 1. The electrical sheets are missing the fire riser room. Please revise the plans to include this room and the required illumination. [Ref. IBC 2018 Sec. 902.1.4] 2. Please indicate an exit sign in the area of door 101B that clearly indicates the direction of egress travel through that door. [Ref. IBC 2018 Sec.1013.1] Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 07/25/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 07/07/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |