Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0625-01267
Parcel: 13213073A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0625-01267
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2025 Commercial Building APPROVED
07/17/2025 Water - PDSD APPROVED
07/17/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/03/2025 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0625-01267 (1650 E TUCSON MARKETPLACE BL TUCSON, AZ 85713)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements.

Outdoor Lighting Review:

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

2. The addition of the exterior lighting fixtures ‘B’ requires compliance with the outdoor lighting code, OLC 102.4.2. See Exception to OLC 102.4.2.
3. Provide the specification sheets for fixture ‘B’ and show lumens at 2000, color temperature no greater than 3500 Kelvin, and fully shielded.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
07/17/2025 Commercial Mechanical REQUIRES RESUBMIT Ventilation for the restroom is required and must be provided whenever the space is occupied (i.e. not just when the temperature is greater than 40 degrees Fahrenheit). Reference: Sections 401.2 and 401.3, IMC 2018.
07/17/2025 Commercial Plumbing REQUIRES RESUBMIT 1. Show how the water pipes are protected from freezing. Reference: Section 305.4, IPC 2018.
2. Show that the distance from the hot water source to the hot water termination for the public lavatory complies with the requirements of Section C404.5, IECC 2018 (i.e., 24” for a ½” supply, 6” for a ¾” supply).
3. Provide secondary (overflow) roof drainage. Reference: Sections 1108.1, 1108.2 and 1108.3, IPC 2018.
07/17/2025 Site Engineering REQUIRES RESUBMIT Permit: TC-COM-0625-01267
Location: 1650 E TUCSON MARKETPLACE BL
Review Date: 7/17/2025
Site Engineering Comments:
1. This falls under Unified Development Code.3.3.G.2.A.b with the reconfiguration of an area outside a building, and therefore will require for a Development Package to be submitted in accordance with 2-06.0 of the Administrative Manual. The associated commercial building permit TC-COM-0625-01267 will not be able to proceed forward to approval until a development package is submitted and approved for the site.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
07/16/2025 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: TC-COM-0625-01267
50 E TUCSON MARKETPLACE BL. – PAD-15
General Merchandise Sales, Large Retail Establishment (1st Review)

TRANSMITTAL: July 16, 2025

This site is located in PAD-15 (UDC 4.7.24). General Merchandise Sales, Large Retail Establishment is an allowed use in the PAD.

1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
07/16/2025 Fire New Construction REVIEW COMPLETED
07/02/2025 PDSD Application Completeness Express REVIEW COMPLETED