Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0625-01183
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/08/2025 | Outdoor Lighting | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 08/18/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/18/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please amend plans to add an exterior light by the exterior doors to comply with 1008.2.3 Exit discharge. Illumination shall be provided along the path of travel for the exit discharge from each exit to the public way. For example, provide light for the exterior door. Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 08/08/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0625-01183 (750 E FOOTHILLS DR TUCSON, AZ 85718) 2nd Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). >>> the following comments were not addressed. 1. Provide Fault Current Analysis and show new equipment AIC rating sufficient to withstand the calculated Fault Current. Provide Available Fault Current calculations from TEP transformers to all new equipment, 2017 NEC 110.24. 2. Show new Panels and other new equipment with AIC ratings greater than or equal to the Available Fault Currents calculated, 2017 NEC 110.10. 3. Provide electrical load calculations, for the Main Service and sub-panel, Per NEC 220.40. 4. Show the location of the panel on the Electrical Plan with clear working space compliance, 2017 NEC 110.26(A) Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/18/2025 | Commercial Mechanical | REQUIRES RESUBMIT | The wall insulation requirements on sheet A1.0 are incorrect. The minimum requirements for wood-framed walls in Climate Zone 2 are R13 +3.6 ci or R20. The exterior wall section you show on delta 1 of sheet A2.0, however, is acceptable based on Table C402.1.3, IECC 2018. [Initial comment: Specify the required maximum U-factors and Solar Heat Gain Coefficients (SHGC) for the doors on the architectural drawings. Reference: Section C103.2, IECC 2018.] | ||
| 08/18/2025 | Commercial Plumbing | REQUIRES RESUBMIT | “Secondary roof drain systems shall have the end point of discharge separate from the primary system.” The secondary (overflow) scupper therefore cannot be located above the primary scupper. In addition, the secondary scupper is typically located only 2inches above the primary scupper unless the roof structure is designed for the additional water weight. Note: a single 8” x 4” primary scupper with an 8” x 4” secondary scupper can easily accommodate the storm drainage for the 200 square foot building (see Table 1106.2, IPC 2018). [Initial comment: Provide secondary (overflow) roof drainage. Reference: Sections 1108.1, 1108.2 and 1108.3, IPC 2018.] | ||
| 08/13/2025 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0625-01183 750 E FOOTHILLS DR – C-1 Adding an ADU type office suite (two offices) (2nd Review) TRANSMITTAL DATE: August 13, 2025 This comment was not addressed. Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the C-1 zone (UDC 4.7.20). Residential Care Services is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.7.J.3.d, .4, & .8 and 4.9.13.O 1. This comment was not addressed. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A Development Package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 08/18/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 08/04/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |