Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0625-01182
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/26/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1.Please provide a cover sheet to include, Code Analysis should also be present detailing the type of construction, occupancy classification(s), occupancy loads, exiting requirements, fire sprinklers and fire alarms. Cover sheet must include a legend of symbols and abbreviations used throughout the plan set. SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Please provide complete set of plans to include a fully dimensioned architectural/civil site plan (not an aerial photograph) showing project address including suite numbers and legal description. SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf A. Show all easements with dimensions, lot area, north arrow, and scale. B. Show the location of all property lines, structure to property line setback dimensions (existing and proposed). C. Show proposed and existing utility meters, public sewer connections, sump pumps, back flow devices, grease interceptors and fire hydrant locations and the type and size of all underground utility lines. D. Please provide street names for all adjacent streets, a fully dimensioned parking plan including tabulation of existing, proposed and required parking spaces. E. Locations of all buildings/structures on adjacent property within 10 feet of property line, including location. F. Provide dimensions of all walkways and driveways related to ADA considerations. G. Submitted plans must follow the approved entitlements for the project and any conditions of approval. 3. Please include the following Architectural Drawings A. Floor Plan to include, A fully dimensioned floor plan including room and/or suite numbers, showing all walls, structural elements, proposed fire-resistant construction including details, and a complete and clear means of egress plan for each floor. B. Building and Wall Sections to include all heights, materials of construction, non-related and fire-rated assemblies, and fire rated penetrations. C. Architectural Details to include building sections referencing all connections, roofing material, roof covering attachment requirements. .SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 3. Please provide the structural calculations used in the design of this project. Prepared and sealed by an Arizona licensed registrant. SECTION 107 of the 2018 IBC and the PDSD Building Plan Requirements 4. Provide a project specific statement of special inspections. IBC 1704.3 5. Please amend the Special Inspections area to list the required special inspections. Additionally, provide the City of Tucson Special Inspection Certificate(s) with Parts A and B completed with the next submittal. IBC 107.1 SI form link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 09/24/2025 | Fire New Construction | REQUIRES RESUBMIT | -Please provide a better site plan showing the surrounding building and the canopy location. This address has multiple buildings on site. -Provide fire propagation/flame spread index information of fabric per IBC 3105.3 john.vincent@tucsonaz.gov 5203495581 |
||
| 10/01/2025 | Site Engineering | REQUIRES RESUBMIT | Permit: TC-COM-0625-01182 Location: 3950 E IRVINGTON RD Review Date: 10/1/2025 Site Engineering Comments: 1. Provide a complete fully dimensioned site plan to show where exactly the proposed structure is going. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 10/01/2025 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0625-01182 3950 E. Irvington Rd. Tucson, AZ 85714 Gable Style Steel Awning (1st Review) TRANSMITTAL DATE: 10/1/2025 The site is located in PAD-34 (TEP Irvington Campus PAD). Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: The included building plans are missing a site plan. Please include a site plan that matches the approved Development Package (TD-DEV-0524-00157). 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 09/11/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |