Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0625-01178
Parcel: 117050090

Address:
434 N 4TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0625-01178
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2025 Site Zoning Standard APPROVED
07/14/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/11/2025 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Please amend the plans to include an Arizona licensed registrant’s seal on each sheet on the drawings to comply with Section R4-30-304 of the Rules of the Arizona State Board of Technical Registration states that in addition to signing the seal, the registrant shall include the date the document was sealed. IBC 107.2.1
2. Please amend the plans so the construction drawings (Sheet A2.1) show the same detailed information as the key plan (page 5) in the structural calculations. IBC 107.2.1 Possibly the markups did not carry over to the construction drawings
3. Please amend the plans to include connection details and a fastening schedule. IBC 107.2.1
4. Please amend the plans to include architectural drawings and detailed drawings of the roof covering to be installed. Showing, roof sheathing type and thickness, underlayment, roof covering materials, fasteners, flashings, penetrations, etc. IBC 107.2.1
5. Please amend the plans to show correct Occupancy classification. IBC 107.2.1 For example C-3 is not an IBC occupancy group please see IBC Chapter 3 and section 303

Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
07/14/2025 Fire New Construction Standard REQUIRES RESUBMIT -Resolve all building comments.
-Correct the occupancy classification on sheet T1.0. You currently have it classified as C3. This is not a type of classification.
-Indicate if the building has fire sprinklers. Sheet T1.0 lists fire sprinklers but then describes a sewer pump system. If the building has sprinklers, a separate permit is required for modification.
-Correct the IFC code year on sheet T1.0. COT/TFD have adopted the 2024 IFC with amendments. Your plans reference the 2018 ed.
john.vincent@tucsonaz.gov
5203495581
06/20/2025 PDSD Application Completeness Express REVIEW COMPLETED