Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0625-01175
Parcel: 11006134E

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0625-01175
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/07/2025 Commercial Mechanical APPROVED
07/02/2025 Site Zoning APPROVED
07/07/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/01/2025 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Sheet C1: Please provide a list of the year and name of the adopted applicable codes from the adopting ordinance. IBC 107.2.1 For example,
2018 International Building Code (IBC)
2018 International Existing Building Code (IEBC)
2009 ICC A117.1 Accessibility Code (by reference)
2018 International Mechanical Code (IMC)
2018 International Plumbing Code (IPC)
2017 National Electrical Code (NEC)
2024 International Fire Code (IFC)
2018 International Fuel Gas (IFGC)
2018 International Energy Conservation Code (IECC)
City of Tucson/Pima County Outdoor Lighting Code
Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes )
2. Sheet A1.1: Please amend plans to show the correct referenced sheet number in the detail callout bubbles. IBC 107.2.1
Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
06/25/2025 Commercial Electrical REQUIRES RESUBMIT Outdoor Lighting Review TC-COM-0625-01175 (2810 N ALVERNON WY TUCSON, AZ 85712)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

Outdoor Lighting Review:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

1. Replacement of the existing outdoor lights requires compliance with the outdoor lighting code. OLC 102.4.
2. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan.
3. List the Lighting Area per OLC chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1.
4. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation.
5. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1.
6. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3).
7. Provide the manufacturers specification sheets for the LED Light Strip to show lumens, color temperature, cutoff status.

8. Specify any exceptions used.

9. Provide Curfew lighting controls If applicable Per section 403 and Table 601.3.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
07/07/2025 Commercial Plumbing REQUIRES RESUBMIT Clarify the size of the reduced pressure zone backflow prevention assembly. On P1.1, it is shown as a new 2” assembly but the water calculations on P3 call out an existing 1” assembly.
07/07/2025 Fire New Construction REQUIRES RESUBMIT Resolve all building comments.
john.vincent@tucsonaz.gov
5203495581
07/07/2025 Water - PDSD REQUIRES RESUBMIT A single 1” water meter (Serial Number 15080399) serves 2802, 2806, and 2810 N Alvernon Wy. Provide the total water demand served by the water meter.
06/20/2025 PDSD Application Completeness Express REVIEW COMPLETED