Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0625-01159
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2025 | Commercial Plumbing | APPROVED | |||
| 07/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/26/2025 | Commercial Building | REQUIRES RESUBMIT | Please submit for utility reconnect for each unit separately and provide complete fire damage repair plans for this unit. Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Plan Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304 2. Please amend the plans to show the area of damage on the site plan or floor plan. IBC 107.2.1 For example, the area could be clouded and named. 3. Plans should indicate the scope of the damage and the required repairs to the damaged areas into code compliance. IBC 107.2.1 For example, like for like repair of sheetrock. Additionally, indicate on the plans if any other items have been damaged, such as framing electrical, plumbing, mechanical. If not damaged, please note on the plans no damage to these areas. If damaged, indicate the repair required and the method used for the repair. Like for Like or specify the replacement. 4. Plans should indicate the governing Building Codes applicable to this repair. IBC 107.2.1 For example, 2018 International Building Code (IBC) 2018 International Existing Building Code (IEBC) 2018 International Mechanical Code (IMC) 2018 International Plumbing Code (IPC) 2017 National Electrical Code (NEC) 2018 International Fire Code (IFC) 2018 International Fuel Gas (IFGC) Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes ) Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 06/25/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0625-01159 (901 N COLUMBUS BL TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Provide a complete electrical plan-set showing all repair work required due to the fire listed in Case: CE-VIO0625-02418. “901 N Columbus has fire and water damage to walls, floors, ceiling, and windows. Unit 901 is condemned due to fire”, “ 901 was running extension cord from 902 N Bryant”. 3. Provide a panel schedule, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 4. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |