Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0625-01148
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2025 | Commercial Mechanical Standard | APPROVED | |||
| 07/02/2025 | Site Zoning Standard | APPROVED | |||
| 07/07/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/30/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. 1. Sheet C1: Please add the 2018 IEBC to the list of applicable codes. IBC 107.2.1 2. so the pull side shows the 18 in clear space adjacent to the latch side of the door. 2009 ICC A117.1 404.2.3.2 3. Sheet A1: Please amend the plans for room #146 to show a space for a wheelchair in the waiting room. ICC A117.1 802.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 06/25/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0625-01148 (2732 N ALVERNON WY TUCSON, AZ 85712) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Show all wiring methods in detail for all new or modified branch circuit conductors and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4. 2. Provide new and updated panel schedules, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 3. Designate the circuit number, that corresponds to the panel schedule, at the location of each new or modified light fixture, receptacle, and equipment disconnect switch or other outlet, NEC arts;300 and 408.4. 4. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/16/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 06/12/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |