Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0625-01127
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/30/2025 | Commercial Building Standard | APPROVED | |||
| 06/10/2025 | Commercial Electrical Standard | APPROVED | |||
| 06/30/2025 | Commercial Plumbing Standard | APPROVED | Shell work only. Approval only on Gas stub out, Water stub out, Grease interceptor stub out. NOTE: complete plumbing information not provided in these drawings. Sizing of grease interceptor, water meter, gas meter will be reviewed at time of Tenant Improvement permit application. | ||
| 06/30/2025 | Commercial Mechanical Standard | NOT REQUIRED | Shell work only. No mechanical information in these drawings. | ||
| 06/30/2025 | Water - PDSD Standard | NOT REQUIRED | Shell only. Information on water consumption and fixture count is not submitted with these drawings. | ||
| 07/01/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/10/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0625-01127 (7101 E 22ND ST TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). Outdoor Lighting Review: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 1. Provide an outdoor site lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan. 2. List the Lighting Area per OLC chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 3. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1. 4. Fixtures installed under canopies and overhangs. Outdoor lighting fixtures shall not be counted in determining the total light output when they are full cutoff light fixtures installed under canopies, building overhangs, or roof eaves, OLC 401.2.1(3). 5. Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf 6. Specify any exceptions used. 7. Provide Curfew lighting controls If applicable Per section 403 and Table 601.3. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/30/2025 | Site Engineering Standard | REQUIRES RESUBMIT | TC-COM-0625-01127 7101 E 22ND ST Site engineering comments are as follows: This commercial building permit cannot be approved until the associated development package, TD-DEV-0525-00137, is approved by all reviewers. UDC Article 3.3.3.7.a Isaac Tineo - isaac.tineo@tucsonaz.gov |
||
| 07/01/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0625-01127 - TD-DEV-0525-00137 7101 E 22ND ST. - C-2 Food Service – Shell Building(1st Review) TRANSMITTAL DATE: July 1, 2025 Provide a detailed response letter with your next submittal that clearly shows how you have addressed all Zoning comments. This site is located in the C-2 zone (UDC 4.7.21). Food Service is an approved use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 and 4.9.13.P. 1. Zoning has reviewed the building plans for compliance with development package (DP) TD-DEV-0525-00137, and although the plans appear to match until the DP is approved by all review agencies and the following comment is addressed Zoning cannot approve the building plan. 2. Sheet SP101 shows a patio railing that runs along the north side of the proposed outdoor patio area. This railing is not shown on the DP and shall be shown on the DP. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/10/2025 | Fire New Construction Standard | REVIEW COMPLETED | CO2 systems requires an operational permit from the Tucson Fire Department City of Tucson Adopted fire code is the 2024 IFC. |
||
| 06/10/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |