Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0625-01100
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/23/2025 | Site Zoning | APPROVED | |||
| 06/23/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/16/2025 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0625-01100 ADDRESS/PARCEL: (1712 W ANKLAM RD Unit: UNIT 102 TUCSON, AZ 85745) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. Two suites are being combined into one of which suite 102 is being used only. a. A new certificate of occupancy shall be generated to reflect this condition. Please provide all information required to complete the certificate of occupancy form correctly. b. Complete the Code Analysis to include the following: i. Provide the description of the activity that will be operating in this space. Is it doctor’s offices, is it an outpatient facility or is a behavioral health facility, etc. ii. Provide the occupant load calculation. iii. Provide the minimum plumbing fixture calculation, what is required and what is provided. iv. On the floor plan, locate and label the drinking fountain(s), service sink & restrooms. c. Provide the floor plan for the Means of Egress. The combining of the two suites may have changed the pattern. i. Ensure to show the length of travel. ii. At the point of exit, enumerate the exit width required and exit width provided and the number of occupants exiting at the point of exit. 2. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 06/05/2025 | Fire New Construction | REVIEW COMPLETED | |||
| 06/05/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |