Permit Number: TC-COM-0624-01275
Parcel: 141390010

Review Status: Requires Resubmit

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.2

Permit Number - TC-COM-0624-01275
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/17/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
12/17/2024 Special Inspection Certificate Review (Deferred Submittal) REQUIRES RESUBMIT Structural Sheet S0.3 requires the following (Please add this to your list of special inspections onto your Special Inspection Certificate form: FABRICATOR SPECAIL INSPECTION):
1704.2.5 SPECIAL INSPECTION OF FABRICATORS:
SPECIAL INSPECTION OF FABRICATION OF STRUCTURAL STEEL BEING
PERFORMED ON THE PREMISES OF A FABRICATOR'S SHOP IS REQUIRED.
EXCEPTION: SPECIAL INSPECTIONS OF FABRICATORS WITH ONE OF THE
FOLLOWING QUALIFICATIONS IS NOT REQUIRED:
• INTERNATIONAL ACCREDITATION SERVICE, INC. (IAS) APPROVED
FABRICATOR.
• AISC CERTIFIED FABRICATOR (STD).
THE SPECIAL INSPECTOR SHALL VERIFY THAT THE FABRICATOR
MAINTAINS DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES
THAT PROVIDE A BASIS FOR INSPECTION CONTROL OF THE
WORKMANSHIP AND THE FABRICATOR’S ABILITY TO CONFORM TO
APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED STANDARDS.
THE SPECIAL INSPECTOR SHALL REVIEW THE PROCEDURES FOR
COMPLETENESS AND ADEQUACY RELATIVE TO THE CODE REQUIREMENTS
FOR THE FABRICATOR’S SCOPE OF WORK.
12/12/2024 PDSD Application Completeness REVIEW COMPLETED