Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01275
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/05/2024 | Water - PDSD | APPROVED | |||
08/05/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/05/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 7/2/2024 1:14:01 PM 1. General: The geotechnical report that has been provided is not for this project. Provide a correct geotechnical report for this project. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 7/2/2024 1:09:54 PM 1. Sheet A3.1.0 / UL 419: UL fire resistant rated wall assemblies typically use proprietary materials as part of the testing process for the listing. Please provide the most recently published complete listed assembly for UL U491. The most recent version of this assembly, as published by UL is dated June 14, 2024. (2018 IBC Sec. 703.2) This would require that you cut and paste the entire most recently published UL Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 7/2/2024 5:00:44 PM 1. General: No required plumbing fixture calculations have been provided. Provide detailed plumbing fixture calculations. |
||
08/02/2024 | Site Engineering | REQUIRES RESUBMIT | see zoning comment | ||
07/30/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0624-01275 - TD-DEV-0424-00110 9210 E VALENCIA RD. - C-2 Financial Service: Excluding non-chartered institutions ( Review) TRANSMITTAL DATE: July 30, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Financial Service: Excluding non-chartered institutions is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.4.L.3, 4.9.13.E, and 4.9.13.P. 1. Zoning has reviewed the building plans for compliance with development package TD-DEV-0424-00110 and although it appears that the building plans comply with the DP, until DP is approved by all review agencies, Zoning cannot approve this building plan. 2. The development package sheets provided in the building plan set either need to be the stamped approved plans, marked for reference only, or removed from the building set. If you elect to mark for reference only do not mark the utility plans and if you elect to remove the plans leave the utility plans in the so Plumbing can review. 3. There are site details that don’t match the details that are shown on the DP, i.e. Accessible sign and bike rack. Either remove them from the building plan or make sure they match the DP. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
08/01/2024 | Fire New Construction | REVIEW COMPLETED | |||
07/01/2024 | PDSD Application Completeness | REVIEW COMPLETED |