Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01273
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/30/2024 | Commercial Electrical | APPROVED | |||
07/30/2024 | Site Zoning | APPROVED | |||
08/02/2024 | Site Engineering | NOT REQUIRED | |||
08/06/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/05/2024 | Commercial Mechanical | REQUIRES RESUBMIT | 1. Revise the section references in the IECC Notes (sheet M2) to correspond to the Commercial Provisions of the 2018 IECC. 2. Provide air balancing data for the Type I hood, the makeup air unit, exhaust fans, and other sources of outside air to verify that the room pressure remains essentially neutral. Reference: Section 501.4, IMC 2018. 3. Smoke detectors shall be installed in the return air duct, upstream of any outside air connections, for all air distribution systems moving than 2,000 CFM (See keynote 2, Sheet M2). Reference: Section 606.2.1, IMC 2018, as amended by the City of Tucson. |
||
08/05/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. New gas-fired cooking appliances are scheduled for installation under the Type I hood. Show how the complete natural gas piping system will be modified. Provide a natural gas piping design, including the piping layout on a floor plan and a natural gas schematic showing the sizes, loads and developed lengths of the piping. Reference: Section 107.2.1, IBC 2018. 2. Revise the location of the existing indirect waste receptor that is shown located under the Turbo-Air refrigerator and the point-of -sale cash register to be visible for inspection and with ready access for cleaning or remove the indirect waste receptor. Reference: Section 802.4, IPC 2018. |
||
08/06/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Sheet A2: Please amend plans to provide life safety/means of egress plan showing the following A. The total number of occupants for the story or floor is shown. IBC 107.2.3 B. The number of occupants is shown for every room and space. IBC 107.2.3 C. The occupant load factor and area are shown for every room and space. IBC 1004.5 D. The occupant load factor used reflects the use/function of the space. IBC 1004.5 E. Assembly occupancy spaces show occupant load signage. IBC 1004.9 F. The number of occupants being served by each egress door is shown. IBC 107.2.3 G. The size of each egress door is shown and is compared to allowable. IBC 1005.3 H. The paths of egress are shown. IBC 107.2.3 I. The path of egress does not pass through kitchens, storage rooms, or similar spaces. IBC 1016.2 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
07/31/2024 | Historic | REQUIRES RESUBMIT | Project is located within the West University HPZ and requires review and approval of the plans by the advisory boards. Please provide the documentation noted in the Historic & Special Districts Application Instructions under Full review (https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf). Once assembled, submit it under the Historic Sub-Record. Questions? jodie.brown@tucsonaz.gov | ||
08/01/2024 | Fire New Construction | REVIEW COMPLETED | |||
07/01/2024 | PDSD Application Completeness | REVIEW COMPLETED |