Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.2
Permit Number - TC-COM-0624-01208
Review Name: COMMERCIAL REVIEW - LIMITED v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/05/2024 | Commercial Electrical | APPROVED | |||
09/09/2024 | Commercial Mechanical | APPROVED | |||
09/09/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/30/2024 | Commercial Building | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 11. Sheet A1.1: Please amend plans to show how the requirements for the kitchenette are in compliance with 2009 ICC A117.1 Section 804. This would include clear floor space, controls, heights, reach, etc. For example, show/specify an accessible work surface 804.3, clear floor space centered on each appliance 804.5, operable parts 804.5.2, cooktop 804.5.4, oven 805.5, and Refrigerator/Freezer 804.5.6. Comment partially remains and is expanded: Please amend plans to provide or modify the following. A. Provide a 30” wide work surface (2009 ICC A117.1 804.3) next to the cooktop/range with a clear floor space complying with Section 305, positioned for a forward approach, provided. Knee and toe clearance complying with Section 306 shall be provided. 2009 ICC A117.1 902.1 http://codes.iccsafe.org/content/icca117-12009/chapter-8-special-rooms-and-spaces#ICCA117.12009_Ch08_Sec804.3 http://codes.iccsafe.org/content/icca117-12009/chapter-9-built-in-furnishings-and-equipment#ICCA117.12009_Ch09_Sec902.2 B. Please modify kitchen layout to ensure the 30”X48” wide, parallel approach clear space centered in front of the Cooktop/Range is free of encroachment by the refrigerator. Currently about 6” of the refrigerator is in this clear space. http://codes.iccsafe.org/content/icca117-12009/chapter-8-special-rooms-and-spaces#ICCA117.12009_Ch08_Sec804.5.1 http://codes.iccsafe.org/content/icca117-12009/chapter-3-building-blocks#ICCA117.12009_Ch03_Sec305.3 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
09/09/2024 | Commercial Plumbing | REQUIRES RESUBMIT | 1. Comment not addressed. [Initial comment: Identify the source of domestic hot water. If the water heater is being installed, provide a detail of the water heater installation, including the excess pressure relief, expansion tank, vacuum relief or other anti-siphon device, safety pan, and valves. Reference: Sections 503.1, 504, 606.1, 607.2, and 607.3, IPC 2018.] 2. Comment not addressed. The notes describing the hot water recirculation, the piping drawing, and the placement of a recirculation pump do not appear to result in a working hot water recirculation system. In addition, hot water recirculation systems are required to have controls that automatically turn off the recirculation pump when there is no hot water demand. Reference: Section C404.6.1, IECC 2018 [Initial comment: Verify that the distance from the hot water source to the hot water termination for the lavatories complies with the requirements of Section C404.5, IECC 2018.] |
||
08/22/2024 | PDSD Application Completeness | REVIEW COMPLETED |