Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01171
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/24/2024 | Site Engineering | APPROVED | |||
07/16/2024 | Site Zoning | APPROVED | |||
07/25/2024 | Commercial Mechanical | NOT REQUIRED | |||
07/25/2024 | Commercial Plumbing | NOT REQUIRED | |||
07/29/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
07/18/2024 | Commercial Electrical | REQUIRES RESUBMIT | TC-COM-0624-01171 Please address the electrical plan review comments and provide a written response. 1 Please provide complete electrical power and lighting plans, sealed by a registrant registered in the state of Arizona. See City of Tucson Electrical Commercial Plan Submittal Requirements can be downloaded at www.tucsonaz.gov/pdsd; Permit Review; Commercial Permits; Commercial Plan Review. Include branch circuit designations, panel schedules, Indicate clearly all light fixture symbols and their associated inverter. Provide complete compliance with the Tucson/Pima County Outdoor Lighting Code. Ref; 2018 IBC sec. 107.2.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements, 2012 Tucson/Pima County Outdoor Lighting Code |
||
07/29/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Please amend plans so the Designer’s seal, signature, and the date signed on all sheets. City of Tucson Submittal Requirement. IBC 107.1 For example, Sheet ID101-ID607 2. Sheet G1: Please amend plans to specify a complete list of the year and name of the adopted applicable codes from the adopting ordinance, applicable to this project. IBC 107.2.1 For example, 2018 International Existing Building Code (IEBC), 2009 ICC A117.1 Accessibility Code (by reference), Local Amendments to Above Codes ( www.tucsonaz.gov/pdsd/building-codes ) 3. Sheet G1: Please amend the Index of Sheets to list all the drawing sheets in this permit’s scope. IBC 107.2.1 Please include sheets A3.0 and A6.1 in the list. 4. Sheet G1: Please amend the plans to provide a detailed description of the work involved in this permit’s scope. IBC 105.3 For example sheets A2.1, A2.2 & A2.3 appear to be exterior demolition sheets. Pleas explain these why sheets were apparently included in this set. Are they to be included in the scope? 5. Sheet G1: Please amend plans to include all the occupancy classifications/groups it contains. IBC 302.1 For example, is there an S occupancy? 6. Please amend the Code analysis to specify the separation type used. Buildings with more than one occupancy classification identify the mixed occupancy methodology as either accessory, nonseparated, separated, or a stated combination of types. IBC 508.1 7. Sheet A6.1: Please provide a detail of ramp/stair handrail extension termination. 2009 ICC A117.1 505.10 8. Sheet A6.1: Please amend plans to provide a detail of the ramp/stair handrail extension termination. 2009 ICC A117.1 505.10.3 9. Sheet A6.1: Please amend plans to provide a detail of the ramp/stair handrail return to wall. IBC 1014.6 10. Sheet A6.1: Please amend the plans to dimension the stair treads and risers. IBC 1011.5 11. Sheet A6.1: Please provide construction details, design and calculations for Lobby guard construction in accordance with IBC 1607.8 Handrails and guards shall be designed to resist a linear load of 50 pounds per linear foot in accordance with Section 4.5.1.1 of ASCE 7 12. Sheet ID 503 Please amend plans to provide Knee and toe clearance at accessible bar seating. 2009 ICC A117.1 306, & 902 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
06/24/2024 | Fire New Construction | REVIEW COMPLETED | |||
06/20/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |