Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0624-01148
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/01/2024 | Commercial Electrical | APPROVED | |||
| 06/25/2024 | Site Engineering | NOT REQUIRED | |||
| 07/03/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/01/2024 | Commercial Building | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0624-01148 ADDRESS/PARCEL: (3168 E KLEINDALE RD TUCSON, AZ 85716) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. COMMENTS: 1. Thank you for informing the City regarding Old Pueblo Community Services where they provide crucial services for homeless housing, support on addictions/Sober Living, mental illness/Behavioral Health, Group Home, etc. Please confirm/indicate which of these services will be used for each building and enumerate it within the code analysis. Please complete the code analysis. 2. For proper inspection to occur, Identify what is to remain existing as well as new work being performed during this transition as well as any work that occurred between the last permit and today. 3. Accessible units Type A and Type B required, also comply to Chapter 11 of ICC ANSI A117.1 and IEBC 305.8.6 accessible units requirement pointing to IBC 1107. IBC 1107 & Table 1107.6.1.1. Label the units whether they are unit A type or B type. 4. Building A must have its own separate building permit. (TC-COM-0624-01148 can be used) 5. Building B must have its own building permit. 6. Building C must have its own building permit. 7. Building D must have its own building permit. 8. Storage Buildings E, F, G can be in another separate building permit. (Please complete the floor plan, add the fenestrations such as doors, etc.) Please indicate what are being stored in these storage buildings, are they flammable or anything that may cause a dangerous situation. Provide fire rated walls where required where structure is adjacent to another use/space/structure. 9. Please resubmit. |
||
| 07/03/2024 | Commercial Mechanical | REQUIRES RESUBMIT | Revise the submitted documents to show any changes that have been made for this address since the final inspection of the last permit. | ||
| 07/03/2024 | Commercial Plumbing | REQUIRES RESUBMIT | Revise the submitted documents to show any changes that have been made for this address since the final inspection of the last permit. | ||
| 06/21/2024 | Fire New Construction | REQUIRES RESUBMIT | -Explain the current use and if this is a change of use. john.vincent@tucsonaz.gov 5203495581 |
||
| 07/03/2024 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Fernando García Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-0624-01148 – Commercial Addition/Alteration – Certificate of Occupancy 3168 E Kleindale Rd, Tucson, AZ 85716 Building Plan Review (1st Review) TRANSMITTAL DATE: July 3, 2024 This site is located in the R-3 zone (UDC 4.7.12). 1. (Comment) Per conversation with applicant and Unified Development Code (UDC) Section 11.3.7.A.3., please clarify use as “multifamily development” on site plan and that this is an existing use, not a change of use. 2. (Comment) Annotate property line dimensions. 3. (Comment) Annotate vehicular use area dimensions, all building dimensions, carport, ramada and patio dimensions, and setback distances between all structures and adjacent property lines. Annotate distances to rights-of-way, including for Kleindale Rd. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Updated site plan. If you have any questions about this transmittal, please contact Fernando L. Garcia at fernando.garcia2@tucsonaz.gov. |
||
| 07/03/2024 | Water - PDSD | REQUIRES RESUBMIT | 1. Show the location and size of the existing water meter (meters?), backflow preventer, and the water service pipe on the site plan. 2. Reduced pressure backflow prevention assemblies are required at the water meter for licensed, personal care facilities. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf 3. Provide the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018. |
||
| 06/17/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |