Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01142
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/24/2024 | Site Zoning | APPROVED | |||
06/13/2024 | Fire New Construction | NOT REQUIRED | |||
07/24/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/25/2024 | Commercial Electrical | REQUIRES RESUBMIT | Permit Review TC-COM-0624-01142 (440 N GRANDE AV TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). General: 1. Each separately metered system will require an individual permit. You will need two separate permits for Building 2 and Building 3 systems. These permits can share the same master Plan-set: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/submitting-for-multiple-permits-on-one-plan-set.pdf 2. This permit (TC-COM-0624-01142) can cover Building 1. 3. You will need to file a Change of address request in order to show the correct address and building number on the permit. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/withdraws-and-extensions.pdf. On step #5, apply for change of address. Provide the complete address, and the building number to be added to the permit. 4. Resubmit updated plans to show the correct address and building numbers for each meter. Plan-Review (Electrical): 5. The provided plans are not fully legible. There are extra characters printed over all the plan text making it difficult to impossible to read. Please submit a plan-set that is fully legible. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
07/22/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. Sheet S0.1: Please amend Design Loads, Wind Load, Basic Wind Speed to read 100 mph to meet the amended IBC Section 1609.1.1 Determination of wind loads. REVISE Section by ADDING the following after the last paragraph: Per the Basic Wind Speed Figures, use the following: Risk Category I – 100 mph Risk Category II – 105 mph Risk Category III – 110 mph Risk Category IV – 115 mph Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
07/16/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Address electrical/other comments. Site Engineering has no objections to the proposed installations. Mike Ortiz michael.ortiz@tucsonaz.gov |
||
06/13/2024 | PDSD Application Completeness | REVIEW COMPLETED |