Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01099
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/16/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/19/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/19/2024 2:51:27 PM 1. General: The Special Inspection Package, has not been provided. Provide the following: ◦ Provide a copy of the Statement of Special Inspections and Schedule of Special Inspection Services forms that are completed, signed, and sealed by the project design engineer. (2018 IBC Sections 1704.2.3 & 1704.3) ◦ Designate in writing the Special Inspection Firm to be used for this project. (2018 IBC Section 1704.2.1) This is a letter from the Special Inspection Firm recognizing their contracted involvement with the project. ◦ The letter from the Special Inspection Firm must specifically identify the members of staff assigned to the project. The letter must include the resume of the individual employees associated with the project to verify their professional qualifications to perform the inspections. This information must be provided. (2018 IBC Section 1704.2.1) ◦ Provide a copy of the Contractor’s Statement of Responsibilities, This form will act as acknowledgement of awareness of the special requirements contained in the Statement of Special Inspections. (2018 IBC Sec. 1704.4) Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/19/2024 2:50:57 PM 1. General: No egress plan has been provided. Provide a detailed egress plan. 2. General: Roof drainage sizing calculations have not been provided. Provide roof drain sizing calculations to the roof plan in accordance with 2018 IPC Section 1106.1 & 1106.2. 3. General: GPM discharge amounts have not been provided for the roof/drain overflows. Provide the roof/drain overflows in accordance with 2018 IPC Section 1106.2 Mechanical(M) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/19/2024 2:51:12 PM 1. General: Please demonstrate compliance with the 2018 International Energy Conservation Code (2018 IECC), as adopted and amended by the City of Tucson. The available options are to meet the prescriptive requirements of 2018 IECC Chapter 4; meet the requirements of the 2013 edition of AHRI/ASHRAE 90.1 (Energy Standard for Buildings Except Low-rise Residential Buildings) or an energy analysis of the proposed building. (2018 IECC Section R401.2) Electrical(E) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/19/2024 2:51:06 PM 1. General: Please demonstrate compliance with the 2018 International Energy Conservation Code (2018 IECC), as adopted and amended by the City of Tucson for any new Interior and Exterior Lighting. The available options are to meet the prescriptive requirements of 2018 IECC Chapter 4; meet the requirements of the 2013 edition of AHRI/ASHRAE 90.1 (Energy Standard for Buildings Except Low-rise Residential Buildings) or an energy analysis of the proposed building. (2018 IECC Section R401.2). Plumbing(P) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 6/19/2024 2:51:20 PM 1. General: To ensure compliance of the gas line design the Gas type, Inlet pressure, Pressure Drop, and Specific Gravity, also provide a gas load summary, the size of all piping (this information is lacking at the piping feeding the fixtures and the amount of BTUs coming in at meter. Please provide more details for the sizing of the gas lines according to 2018 IFGC Section 402.3. 2. General: No gas riser diagram has been provided. Provide the following information: lengths of gas piping from supply to outlets, inlet pressure, Pressure drop, and specific gravity used in the design of this system. 3. General: The grease trap sizing calculations have not been provided. Provide detailed grease trap sizing calculations in accordance with 2018 IPC Section 1002. |
||
| 06/24/2024 | Fire New Construction | REQUIRES RESUBMIT | -Resolve all building comments. -Conflicting information on sheet T1.0 as it relates to fire sprinklers. Building information for type of construction and travel distance show "unsprinklered." Project summary, on same page, shows fire sprinklers and fire alarm to be installed per NFPA standards. John.vincent@tucsonaz.gov 5203495581 |
||
| 07/08/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 07/01/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0624-01099 - TD-DEV-1023-00428 6105 E BROADWAY BL. – I-1 Food Service (1st Review) TRANSMITTAL: July 1, 2024 Resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the I-1 zone (UDC 4.7.29). Food Service, Excluding Soup Kitchens is a allowed use in the zone (UDC Table 4.8-5). 1. As Development Package (DP) TD-DEV-1023-00428 has not yet completed it’s 1st review Zoning is not able to review the building plans for compliance with the DP and will review on the next submittal. 2. Based on the sheet index you will be providing development package sheets in the building set. The development package sheets provided in the building plan set either need to be the stamped, approved plans, or marked for reference only. If you elect to mark for reference only do not mark the utility plans and if you elect to remove the plans leave the utility plans in the so Plumbing can review. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 07/16/2024 | Water - PDSD | REQUIRES RESUBMIT | Coordinate the civil and plumbing designs for the water service to the building. The civil drawings show a 2” water service pipe while the plumbing drawings call for a 1-1/2” water service pipe. | ||