Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0623-01623
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/06/2023 | Site Zoning | APPROVED | |||
07/31/2023 | Water - PDSD | APPROVED | |||
07/10/2023 | Site Engineering | NOT REQUIRED | |||
07/31/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/24/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 7/24/2023 8:48:53 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Conditionally Approved Reason: Date Completed : 7/12/2023 1:38:17 PM 1. Ensure that the tenant separation wall maintains it required fire resistance rating. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Denied Reason: Date Completed : 7/3/2023 1:32:59 PM 1. Smoke detectors shall be installed in return air systems with a design capacity greater than 2,000 cfm (IMC2018,606.2.1) 2. The duct smoke detectors shall be tied into the building fire alarm Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 7/11/2023 11:36:09 AM Electrical Review JD Sports By: Ron Ross PE E-111 ELECTRICAL POWER PLAN: Could not locate Keynote 13. E-112 ELECTRICAL POWER PLAN: Keynote 4 seems to be in the wrong location. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 7/15/2023 12:07:39 PM First Plumbing Review: 1). Lavatory faucet on plan page P-001 needs to be an automatic type. Tucson Amendment 412.11, 419.6 2). Lavatory faucet on plan page P-001 needs an ASSE 1070 mixing valve - IPC 419.5 3). Floor drain on plan page P-001 needs trap primer or trap guard 1002.4.1 |
||
07/20/2023 | Fire New Construction | REVIEW COMPLETED | |||
06/30/2023 | PDSD Application Completeness | REVIEW COMPLETED |