Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0623-01535
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/07/2023 | Water - PDSD | APPROVED | |||
09/07/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
08/21/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 8/21/2023 9:02:39 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 8/18/2023 12:48:09 PM 1. Sheet A1.1: The egress balcony requires wall separation between the balcony and the structure. The exception of Section 1021.2 does not apply due to the dead end. Provide a properly rated wall between the egress balcony and the structure in accordance with Section 1021.2. See Section 1020.1, Section 708.3 w/ exceptions. Notate any exceptions on the plans. NOT COMPLIED. ◦ NOTE: The length of the dead end condition is not in question. A dead end condition less than 50' in length is permitted. The exception of Section 1021.2 states the separation is not required where the exterior egress balcony is served by not less than two stairways and a dead-end travel condition does not require travel past an unprotected opening to reach a stairway. The dead end travel that exists, travels past two unprotected openings (1 door and 1 window) and thus would require separation as required for corridors for Group R occupancies (1/2 hour for NFPA 13/13R systems) along with protected openings (doors and windows). Provide evidence of compliance that the walls and openings meeting the protection requirements of Section 716 and 1021.2. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/26/2023 11:21:05 PM Approved/Subject to field approval for shell and core phase Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 8/17/2023 4:59:52 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 8/18/2023 10:48:45 PM Second Plumbing Review: ok subject to field inspections 1). Resolved-second floor water heater on plan page P4.1 needs to be in a pan and have its drains piped to a waste receptor or exterior. - IPC 504.6, 504.7. 504.7.2 ** added floor sink at water heater will need trap guard or trap primer, ok subject to field inspections** 2). OK 3). OK 4). OK 5).OK |
||
08/08/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
08/08/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0623-01535 10455 E. Drexel Rd. - PAD-12 New Medical Office Building Shell (2nd Review) TRANSMITTAL: August 8, 2023 Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in PAD-12 (UDC 4.7.24), Medical Office is an allowed use in the PAD. 1. Zoning has reviewed the building plans for compliance with the associated unapproved Development Package TD-DEV-0523-00235. Zoning cannot approve the building plans until the DP is approved. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
08/03/2023 | PDSD Application Completeness | REVIEW COMPLETED |