Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0623-01516
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/25/2023 | Bldg Permits - Post Review | REVIEW COMPLETED | |||
07/24/2023 | External Reviewers - SAFEBuilt | REVIEW COMPLETED | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 7/5/2023 1:19:04 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 7/19/2023 1:58:16 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/19/2023 6:48:12 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 6/28/2023 11:18:16 AM Electrical Review of Costco By: Ron Ross PE Approved with the following: Comment Only E-1 PARTIAL FLOOR PLAN, LIGHTING FIXTURE SCHEDULE, DETAIL, LEGEND AND NOTES: Lighting Fixture Schedule should not reference Chicago City Code Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 7/1/2023 11:03:34 PM |
||
07/12/2023 | PDSD Application Completeness | REVIEW COMPLETED |