Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0623-01516
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/21/2023 | Site Zoning | APPROVED | |||
07/05/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/05/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0623-01516 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 7/5/2023 1:19:04 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 7/3/2023 11:21:17 PM 1. Clarify if any work to the fire sprinkler and fire alarm systems will be under a differed submittal. 2. Provide a life safety/ exit plan on the drawings that indicates the travel distances from the most remote points as well as the occupant loads for the areas to be remodeled in accordance with 2018 IBC 1004 and 1017.2. 3. Indicate on the finish schedule that all interior finishes will be in accordance with 2018 IBC 803.1 Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Approved with Comments Reason: Date Completed : 6/19/2023 6:48:12 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved with Comments Reason: Date Completed : 6/28/2023 11:18:16 AM Electrical Review of Costco By: Ron Ross PE Approved with the following: Comment Only E-1 PARTIAL FLOOR PLAN, LIGHTING FIXTURE SCHEDULE, DETAIL, LEGEND AND NOTES: Lighting Fixture Schedule should not reference Chicago City Code Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 7/1/2023 11:03:34 PM |
||
07/05/2023 | Fire New Construction | REVIEW COMPLETED | |||
06/16/2023 | PDSD Application Completeness | REVIEW COMPLETED |