Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0623-01500
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/16/2023 | Site Zoning | APPROVED | |||
06/29/2023 | Site Engineering | NOT REQUIRED | |||
07/03/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/30/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0623-01500 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 6/30/2023 1:29:40 AM Provide detail of hood support. Building(B) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 6/30/2023 1:42:23 AM Provide separate toilet facilities for each sex per IBC 20902.2 Mechanical(M) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 6/30/2023 12:42:53 AM IBC as amended 940.12.2 states that the actuation of the fire suppression system shall automatically shut down the electrical power supply to the cooking equipment and all electrical receptacles located under the protected exhaust hood. Provide detail of hood support. Electrical(E) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 6/30/2023 12:37:32 AM IBC as amended 940.12.2 states that the actuation of the fire suppression system shall automatically shut down the electrical power supply to the cooking equipment and all electrical receptacles located under the protected exhaust hood. Verify emergency lighting meets IBC 1008.3.5 Illumination level under emergency power. Plumbing(P) Reviewer Matthew Payette mpayette@safebuilt.com Denied Reason: Date Completed : 6/30/2023 1:13:29 AM Provide automatic faucets in accordance with 412.11 of the 2018 IPC as amended. Update plumbing - waste plan to comply with 1003.3 of the 2018 IPC as amended. Section 1003.3 Grease interceptors of the IPC has been deleted and replaced with a list of fixtures to be connected to a grease interceptor located within the kitchen area or subject to grease waste*: Pre-rinse and or pre-wash sinks, Two or three compartment sinks, Meat prep sink; Wok stoves; • Self-cleaning stove ventilation/exhaust hood; • Kitchen floor drains; • Floor sinks; • Mop sinks; • Food prep sinks; • Hand sinks**; • Dishwasher; and • Food waste disposal units***. * Depending on use and context, the requirement for above listed fixtures to drain through an interceptor may be appealed to RWRD. ** A hand wash sink located in the kitchen area shall either discharge through a grease interceptor or have a sign posted above it stating: “HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED.” *** Discharges from food waste disposal units must drain through a maximum 3/8 inch screen. Provide separate toilet facilities for each sex per IBC 20902.2 |
||
07/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
06/14/2023 | PDSD Application Completeness | REVIEW COMPLETED |