Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0623-01492
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/15/2023 | Site Zoning | APPROVED | |||
| 07/03/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/30/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0623-01492 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 6/29/2023 2:34:27 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/29/2023 2:14:30 AM 1. The plans note that the existing doors in the conference room are to be closed off on the interior side. Clarify what closed off means, it is not clear if these doors are to be locked or if some type of partition is to be installed. Note 28 AD-101a and note 11 on sheet A101a. 2. Correct the exterior door notes on sheet AD-101b that indicate note 6, it appears it should be note 2. 3. Clarify if there is to be an exit sign above the new door 105 outside of the employee break area. This door is not indicated as an exit from the shop. Sheet A-151a. 4. Indicate on the drawings that Fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. 5. Indicate that all interior finishes will be in accordance with 2018 IBC 803.1. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/15/2023 8:24:13 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 6/26/2023 7:18:11 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/25/2023 1:13:53 PM First Plumbing Review: 1). Plan page P101B doesn't show any piping illustrations to the eye wash that is shown on plan page A103B 2). Fixture schedule on plan page P-201 needs to include the Eye wash that is shown on plan page A103B -IPC 411 3). The lavatory mixing valve on the fixture schedule on plan page P-201 needs to be ASSE 1070 rated -IPC 419.5 |
||
| 07/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
| 06/14/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |