Permit Review Detail
Review Status: Requires Resubmit
Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Permit Number - TC-COM-0623-01485
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/06/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/06/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | High Pile Storage Designs Structural(S) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 5/29/2024 2:17:13 PM 1. Sheet 2/HPS notes “Racks are Hannibal In static frame MODEL IF3014, al and structural engineering manufacturer but these rack documents were not provided. Where is the structural engineer stamp/seal in structural manufacturer’s shop drawings (engineer stamped)? 2. Provide rack anchoring details. How are the secured racks anchored to the floor? Same anchor detail for different height racks (12’ and 20’)? Building(B) Reviewer Kimiyoshi Shimabukuro kshimabukuro@safebuilt.com Denied Reason: Date Completed : 5/29/2024 2:17:35 PM 1. Previous sheet a1.2 warehouse floor plan shows 16’ tall racks while this rack section shows 12’ and 20’ racks. Provide updated plan. 2. Type ll-B non-combustible construction reference but section notes of potential solid 3/8” plywood. Reference building code exception section when applicable. 3. Show the locations of portable fire extinguishers per 2018 IFC 3206.11 and section 906 within 75 feet travel distances. 4. Provide construction documents per 2018 IFC section 3201.3. (14 items listed). Show commodity clearance between top of storage and the sprinkler deflector for each storage arrangement (item 4). Location of commodities that are banded or encapsulated (item 8). Maximum pile volume for each storage array (item 6). Location of required fire department access doors (item 9). Location of valves controlling the water supply of ceiling and in-rack sprinklers (item 11). Type, location and specifications of smoke removal and curtain board systems (item 12). Dimensions and locations of transverse and longitudinal flue spaces (item 13). 5. Class I – IV commodities are identified for this storage so specify the type of commodities in storage layout per 2018 IFC section 3201.3.2 item 3. Show commodity clearances (item 4). Location and classification of commodities in accordance with section 3203 (item 7). Examples of commodity classifications in 2018 IFC Table 3203.8: showing product categories, products and classifications. Mechanical N/A Electrical N/A Plumbing N/A |
||
05/28/2024 | PDSD Application Completeness | REVIEW COMPLETED |