Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0623-01471
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/13/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
09/25/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Denied Reason: Date Completed : 9/21/2023 8:52:52 AM THE FOLLOWING COMMENTS FROM THE PREVIOUS REVIEW ARE NOT ADDRESSED IN THIS SUBMITTAL. 1. Refer to Structural Drawings and Architectural Drawings. The size and Footprint of the buildings do not match. Revise Structural Drawings Foot Print to match Architectural Drawings. 2. Provide Structural Calculations for Foundations and Foundation Loadings from the Prefab Building per Section 1601.1 of International Building Code 2018. 3. Provide Wind Load Calculations for the Prefab Building per Section 1609 of International Building Code 2018. 4. Provide Seismic Calculations for the Prefab Building per Section 1613 of International Building Code 2018. 5. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. 6. Provide Geotechnical Report for the proposed building per International Building Code 2018, Section 1803.1. 7. DEFERRED SUBMITTAL REQUIREMENTS Structural general notes are to include any components of the building that may be considered deferred submittals. IBC Section 107.3.4.1 requires deferred submittals to be approved by the building official. If items will be deferred the plans are to clearly note the following per IBC Section 107.3.4.1: * To be reviewed by design professional in responsible charge. * Design professional shall affix a notation that the deferred items are in general conformance with their design of the building. * They shall be submitted for review by the building official. * Shall not be installed until approved by building official. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/21/2023 11:01:31 AM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/12/2023 10:33:03 PM Approved /subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 9/21/2023 5:52:39 PM Electrical Review By: Ron Ross PE E507 Lighting Schedule: Need to provide an interior lighting Comcheck and a required exterior lighting Tucson city Lumens calculation. The first is to prove IECC compliance, the Lumens calculation is a Tucson requirement. Response indicates that it was performed. However, the reports were not uploaded or included for review. Suggest to put these directly on sheet E507 so that it is included vs overlooked in upload. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 9/23/2023 7:57:22 PM Second Plumbing Review: Sala Garage Plan. See warehouse plan under project #TC-COM-0623-01468 OK Subject To Field Inspections 1). Resolved-Add gutter & downspout sizing calculations to plan page A105 -IPC 1106.1, 1106.3, 1106.6 2)..RESOLVED- Plan set needs to be accompanied by a site utility for the continuation of sanitary, water, fire line, & gas.as stated throughout plumbing pages -IPC 106.3.1 3).RESOLVED-Detail #6 on plan page P503 states water heater DWH-2 utilizes propane, but plan page P504 states water heater DWH-2 Utilizes Natural Gas ? Plan pages need to correlate. -IFGC 106.3.1/NFPA58 4). .RESOLVED-Plan pages P202B-G, P203 show LP Gas system but plan page P504 states water heater DWH-2 Utilizes Natural Gas ? Plan pages need to correlate. -IFGC 106.3.1/NFPA58 5). .RESOLVED-Plan page P504 fixture schedules needs to include high/low drinking fountain manufacturer & model number - IPC 410.1 6). .RESOLVED-Trench drain connections on plan page P601G need traps -IPC IPC 1002.1 7). .RESOLVED-Gas plan page P202B-G needs to illustrate the LP Tank location. -NFPA58 8)..RESOLVED-Gas piping plan page P202B-g needs to included gas system length & sizing table used -IFGC 402.4 9). .RESOLVED-Plan page P003 needs to include LP tank info such as above or underground type & size. -NFPA58 10). .RESOLVED-Gas plans need to include an LP tank detail that includes tank anchoring methods. -NFPA58 11)..RESOLVED-Label The emergency eyewash/shower mixing valve location plan pages P202B-G & P602G , it appears key note symbol #8 on P602G is intended to reflect this info but no correlating notes are included on plan page P602G? -IPC 106.3.1, 411.3 12). .RESOLVED-Plan page P602G is missing the correlating keynote information. -IPC 106.3.1 13). .RESOLVED-plumbing plan page P001 sheet list & plan set cover page plumbing plan sheet list don't match. -IPC 106.3.1 14). .RESOLVED-Plan page P001 sheet list doesn't match plumbing pages sent. -IPC 106.3.1 |
||
10/13/2023 | Site Engineering | REQUIRES RESUBMIT | 1. The permit cannot be approved until the associated development package, TD-DEV-0523-00230, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
10/11/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0623-01468 & TC-COM-0623-01471 7157 S. Swan Rd. – I-2 Transportation Service, Land Carrier (1st Review) TRANSMITTAL DATE: October 11, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the I-2 zone (UDC 4.7.30). Transportation Service, Land Carrier is a permitted use in this zone (Table 4.8-5), subject to Use Specific Standards 4.9.13.Q. 1. Zoning attempted to review the building plans for compliance with Development Package (DP) TD-DEV-0523-00230, but as sufficient information was not provided on the DP such as square footage and height of proposed structures, AM Section 2-06.4.9.Q, Zoning is not able to review the building plans for compliance with the DP. Zoning will review the building plans for compliance with the DP on the next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
10/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
09/19/2023 | PDSD Application Completeness | REVIEW COMPLETED |