Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.3

Permit Number - TC-COM-0623-01460
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/05/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
09/05/2023 Commercial Mechanical REQUIRES RESUBMIT Odor mitigation for this dispensary is limited to ionizers located in each of the three rooftop units. The units take in a total of 520 CFM of outside air but it is not known if the units are equipped with power exhaust. The two restroom exhaust fans, with a total exhaust of 200 CFM, have no provisions for odor mitigation but apparently only operate intermittently. This imbalance of outside air and exhaust can lead to a pressurization of the building with excess air (and odors) flowing out through doors and other openings. Clarify how the proposed HVAC system will be able to prevent internal odors from being emitted from the building.
09/05/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-COM-0623-01460
1010 S. Freeway – C-2
Marijuana Facility; Dispensary (3rd Review)

TRANSMITTAL DATE: September 5, 2023

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the C-2 zone (UDC 4.7.21). Marijuana Facility; Dispensary is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standard 4.9.9.E.1.

1. Clearly demonstrate how all requirements of UDC Article 4.9.9.E.1.I by addressing comments from Commercial Mechanical - odor mitigation plan required - are met. Per UDC 4.9.9.E.1.I - Odor devices and techniques shall be incorporated in all marijuana facilities to ensure that odors are mitigated. As such, this may be done through an exhaust air filtration system with odor control that prevents internal odors from being emitted externally or through any other best practices deemed adequate for odor mitigation as determined by the Zoning Administrator.

If you have any questions about this transmittal, please contact Loran.Shamis@tucsonaz.gov
08/08/2023 External Reviewers - SAFEBuilt REVIEW COMPLETED Structural(S) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 8/7/2023 12:43:13 PM




Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Approved
Reason:
Date Completed : 8/7/2023 12:43:08 PM



Mechanical(M) Reviewer
James Sullivan
jsullivan@safebuilt.com
Approved
Reason:
Date Completed : 6/27/2023 8:23:24 AM
Plans approved for permit issuance



Electrical(E) Reviewer
Janet Matz
jmatz@safebuilt.com
Approved
Reason:
Date Completed : 7/19/2023 1:39:01 AM



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved
Reason:
Date Completed : 7/14/2023 8:02:47 PM
Second Plumbing Review:
1 thru 5 OK
08/04/2023 PDSD Application Completeness REVIEW COMPLETED