Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0623-01460
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/27/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/27/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0623-01460 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/24/2023 1:23:07 AM 1. Provide calculations from a State of Arizona licensed structural engineer indicating that the existing roof is sufficient to hold the new rooftop units. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/24/2023 1:21:54 AM 1. The Architect stamp shall include the date signed as part of the seal. The license expiration date is appreciated but not required. 2. Coordinate the drawings index on sheet G1.0 with the drawings provided in the set. Sheet A1.5 in the index but missing, there are two sheet M2.0, and the power plan drawing indicated as E2.1 is miss marked in the drawings. 3. Provide a written scope of work on the drawings. 4. Clarify if the fire sprinkler and fire alarm plans will be under a separate submittal or include them with the set. 5. Note on the cover sheet that all work will be done in accordance with the following codes as adopted by the City of Tucson: 2018 International Building Code 2018 International Fire Code 2018 International Mechanical Code 2018 International Plumbing Code 2017 National Electrical Code 2018 International Energy Conservation Code City of Tucson/Pima County Outdoor Lighting Code ICC A117.1-2009 Accessible and Usable Buildings and Facilities 1. Show an emergency light fixture on the egress plan in the existing vestibule area on sheet G1.1. 2. Update the dashed line paths on the egress plan sheet G1.1 that are going through walls and furniture. Provide distances on the line segments. 3. The plans indicate closing three existing openings to the neighboring tenant space. It is unknown if the existing doors are part of the egress pathway for the neighboring tenant and how or if this will affect their life safety. Show the neighboring tenant floor plan and indicate the exiting is not through these existing openings to be infilled and closed. 4. Clarify if the existing wall that is now a demising wall between the tenant is required to be fire rated. If so, note it as such on the drawings and indicate that any openings, existing or new within barrier will be filled to match or exceed the fire rating of the wall. 2018 IBC 714. 5. Identify the use of the two areas that indicate “architect unable to access” and the existing space 105 on the floor plan sheet A1.0. 6. Indicate on the drawings that Fire extinguishers shall be installed in accordance with 2018 IFC section 906.2. 7. Indicate on the finish plan notes on sheet A1.2 that all interior finishes will be in accordance with 2018 IBC 803.1. 8. Clarify the ceiling finishes, the partition types on sheet G1.1 indicate a new ACT system however the finish plan on sheet A1.2 indicates a painted ceiling. Coordinate the drawings. If ACT tile as noted in the finish legend on sheet A1.3 is to be used, provide a detail for its hanging support and show the grid on the drawings. 9. Provide a framing plan or other details on how the new 5/8 FR plywood will be supported for the attachment of the security barrier shown above the ceiling in partition type 3 and 5 on sheet G1.1 above the secured storage area. Clarify if this room is to have a painted GYP ceiling or a ACT under the plywood. 10. Provide details for the installation of the new store front doors in Lobby (frame and threshold) into the existing store front aluminum window system. Mechanical(M) Reviewer James Sullivan jsullivan@safebuilt.com Approved Reason: Date Completed : 6/27/2023 8:23:24 AM Plans approved for permit issuance Electrical(E) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/24/2023 1:22:31 AM 1. Update the electrical notes on sheet E0.1 to reflect the 2018 IBC not the 2015. 2. Provide an interior lighting COMcheck or other approved methodology for the project for the new proposed lighting that is in compliance with the 2018 IECC or indicate on the drawings that less than 10 percent of the luminaires in the space are being replaced and such alterations do not increase the installed interior lighting power. C503.6 exception. 3. The reflected ceiling plans indicate an additional exit sign from the new reception area through the existing vestibule 102. Provide an additional exit light above door 102A and an emergency light with battery backup in the vestibule and coordinate the drawings. 4. Indicate the location of an existing emergency light on the exterior at the exit doors to illuminate the landings or indicate new fixtures will be provided. 2018 IBC 1008.3.2 (5). Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/20/2023 10:43:35 PM First Plumbing Review: 1). Lavatory faucets on plan page need to be Automatic type -Tucson Plumbing code amendment 412.11, 419.6 2). Gas roof top units are shown on plan page M2.0 & gas load calcs & piping materials is referenced on plan page P2.0. Plumbing plans need to illustrate the gas piping system -IFGC 106.3.1 3). Plan page P1.1 needs to include water pipe sizes - IPC 604 4). Plan page P1.1 needs to illustrate the hot piping return system - IPC 607.2 5). Plan page P1.0 needs to notate all of the sanitary branch sizes - IPC 710 |
||
06/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0623-01460 1010 S. Freeway – C-2 Marijuana Facility; Dispensary (2nd Review) TRANSMITTAL DATE: June 13, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.21). Marijuana Facility; Dispensary is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standard 4.9.9.E.1. 1. Provide a copy of the 4.9.9.E.1 approved authorization letter with the next submittal. Contact Loran Shamis, Lead Planner, phone (520)837-2242 or email Loran.Shamis@tucsonaz.gov for requirements 2. Clearly demonstrate how all requirements of UDC Article 4.9.9.E.1.k are met. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
06/27/2023 | Fire New Construction | REVIEW COMPLETED | |||
06/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |