Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0526-00788
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2026 | Commercial Building Standard | APPROVED | |||
| 06/18/2026 | Commercial Mechanical Standard | APPROVED | |||
| 06/18/2026 | Commercial Plumbing Standard | APPROVED | |||
| 06/05/2026 | Outdoor Lighting Standard | APPROVED | |||
| 06/22/2026 | Site Zoning Standard | APPROVED | |||
| 06/18/2026 | Water - PDSD Standard | NOT REQUIRED | |||
| 06/22/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/15/2026 | Addressing Validation | REQUIRES RESUBMIT | If you have questions regarding this review, please contact CDRC@tucsonaz.gov. Unable to place documents in review due to addressing issues. The site plan you submitted is missing the project address. Please resubmit the site plan with the complete project address on each page of the site plan. Step-by-Step instructions on how to resubmit: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf |
||
| 06/12/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0526-00788 (3002 E GRANT RD Unit:UNIT 1 TUCSON, AZ 85716) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide AFIC for all electrical outlets as listed in NEC 210.12(B). This includes kitchen outlets. 2. Show two or more 2O AMP small appliance circuits at the kitchen countertop receptacle outlets; they may also serve the breakfast room and dining room, but not other locations, [NEC 210.52(C)(1)] and [NEC 210.52(B)(1)]. GFCI protected, [NEC 210.8(A)]. The provided plans only show one kitchen countertop circuit that is shared with non-code compliant locations. 3. Show GFCI Protection for all receptacles within the Kitchen area, including the fridge, and stove and all wall receptacles, [NEC 210.8(A) item 6]. 4. Show Bathroom receptacles with a separate 20 AMP dedicated circuit, [NEC 210.11(C)(3)] and [NEC 210.52(D)]. GFCI Protected, [NEC 210.8(A)]. The receptacle in the bathroom cannot share the circuit with any other locations. |
||
| 06/20/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 06/03/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |