Permit Number: TC-COM-0526-00765
Parcel: 10711092A

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.4

Permit Number - TC-COM-0526-00765
Review Name: COMMERCIAL REVIEW - FULL v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
08/21/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
08/21/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0526-00765
ADDRESS/PARCEL: 3100 N STONE AV Unit:UNIT 122 TUCSON, AZ 85705

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. The corridor is still being utilized as a return air path for the adjoining rooms. Corridors shall not be used as return air ducts unless one of the exceptions in Section 601.2 applies. Please revise the HVAC system to provide a return air path that does not utilize the corridor, such as providing return air from the individual rooms directly back to the HVAC unit. Reference: Section 601.2, IMC 2024.
08/11/2026 PDSD Application Completeness Express REVIEW COMPLETED