Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0526-00705
Parcel: 12409124A

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0526-00705
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/18/2026 Commercial Plumbing Express REQUIRES RESUBMIT 1. The water service pipe shall not be less than ¾ inch (19.1 mm) in internal diameter. The internal diameter of ¾ PEX is 17.0 mm. Reference: Section 603.1, IPC 2024.
2. Provide a cleanout within 30 inches of the exterior wall of the building and another cleanout prior to entering the right-of-way. Reference: Section 708.1.3, IPC 2024, and Pima County Standard Detail RWRD 401, 2021.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
05/14/2026 PDSD Application Completeness Express REVIEW COMPLETED