Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1
Permit Number - TC-COM-0526-00704
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/18/2026 | Commercial Plumbing Express | REQUIRES RESUBMIT | 1. The water service pipe shall not be less than ¾ inch (19.1 mm) in internal diameter. The internal diameter of ¾ PEX is 17.0 mm. Reference: Section 603.1, IPC 2024. 2. Provide a cleanout within 30 inches of the exterior wall of the building and another cleanout prior to entering the right-of-way. Reference: Section 708.1.3, IPC 2024, and Pima County Standard Detail RWRD 401, 2021. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 05/14/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |