Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: TC-COM-0526-00701
Parcel: 12409124A

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0526-00701
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
05/18/2026 Commercial Plumbing Express REQUIRES RESUBMIT 1. The water service pipe shall not be less than ¾ inch (19.1 mm) in internal diameter. The internal diameter of ¾ PEX is 17.0 mm. Reference: Section 603.1, IPC 2024.
2. Provide a cleanout within 30 inches of the exterior wall of the building and another cleanout prior to entering the right-of-way. Reference: Section 708.1.3, IPC 2024, and Pima County Standard Detail RWRD 401, 2021.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
05/14/2026 PDSD Application Completeness Express REVIEW COMPLETED