Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0526-00678
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/22/2026 | Commercial Building Standard | APPROVED | |||
| 05/29/2026 | Commercial Plumbing Standard | NOT REQUIRED | |||
| 05/20/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 05/22/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 05/29/2026 | Water - PDSD Standard | NOT REQUIRED | |||
| 06/02/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/21/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0526-00678 (382 N COVILLE DR TUCSON, AZ 85745) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide updated electrical load calculations, for the Main Panel showing it can support the additional electrical load, Per NEC 220.40. 2. Provide an updated panel schedules, showing the circuits that are being modified, added or removed or existing. NEC arts;300 and 408.4. Include panel bus rating and A.I.C. rating. IBC 107.1. >>> Adding new 2 ton split system heat pump. 3. Provide an electrical floor plans and Designate the circuit number on the electrical plans, that corresponds to the panel schedule, at the location of each existing, new or modified light fixture, receptacle, and equipment disconnect switch, NEC arts;300 and 408.4. IBC 107.1. |
||
| 05/29/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0526-00678 ADDRESS/PARCEL: 382 N COVILLE DR TUCSON, AZ 85745 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. Provide plans sealed by an Arizona Registrant. Reference: Section 107.1, IBC 2024 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. |
||
| 05/29/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Bobby Parsons Zoning Section Review PROJECT: TC-COM-0526-00678 382 N Coville Dr. Tucson, AZ 85745 Convert Garage to Temporary Sales Office (1st Review) TRANSMITTAL DATE: 5/29/2026 The site is located in the R-1 (UDC 4.7.8) and O-3 (UDC 4.7.15) zones. Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 1. Comment: A separate Temporary Use Permit (TUP) will be required prior to approval of this building permit. If you have questions about the TUP, please contact Mark Castro at Mark.Castro@tucsonaz.gov. 2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 06/02/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 05/11/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |