Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0525-01049
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/12/2025 | Commercial Electrical Standard | APPROVED | |||
| 06/18/2025 | Site Zoning Standard | APPROVED | |||
| 06/03/2025 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting . | ||
| 06/18/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/12/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0525-01049 ADDRESS/PARCEL: (9155 E TANQUE VERDE RD Unit:UNIT 177 TUCSON, AZ 85749) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. The sink in Restrooms are infringing into the required floor clearance area of 60” x 56” at the water closet. Other fixtures not allowed within the required clear area. Please relocated the sink complying to the ANSI accessible requirement per ICC ANSI A117.1 figure 604.3 9. 2. Please indicate on the plan which is Male and which is Female restrooms. 3. Please submit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 06/16/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Provide calculations to verify that adequate ventilation will be provided for the restrooms. Reference: Section 403.3.1.1, IMC 2018. | ||
| 06/16/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Provide tempered water for the lavatories and public hand-washing sinks in restrooms using approved devices conforming to ASSE 1070, not ASSE 1016. Reference: Sections 419.5 and 607.1.2, IPC 2018. 2. Faucets serving lavatories in all buildings other than R3 occupancies, individual units in R2 occupancies, or International Residential Code structures shall be automatic faucets dispensing a maximum of 0.25 gallons per cycle. The cycle time shall not be less than ten-seconds for accessibility. Reference: Section 419.6, IPC 2018 as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. 3. Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018. |
||
| 06/04/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 05/27/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |