Permit Number: TC-COM-0525-01035
Parcel: 13811073C

Review Status: In Review

Review Details: COMMERCIAL REVIEW - FULL v.5

Permit Number - TC-COM-0525-01035
Review Name: COMMERCIAL REVIEW - FULL v.5
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2026 Outdoor Lighting Standard APPROVED
N/A Bldg Permits - Post Review Express PENDING ASSIGNMENT
N/A Commercial Building Standard PENDING ASSIGNMENT
08/06/2026 Commercial Electrical Standard REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0525-01035 (6444 S FONTANA AV TUCSON, AZ 85706)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov

1. Provide a Grounding Electrode System at the detached structure per 250.31(A). Grounding electrode system and grounding electrode conductor. Required.
2. Provide appropriate grounding and bonding of all metal structures, per all relevant sections of NEC 250 (example sections 250.4(A), 250.20, 250,32, 250.104).
3. Provide grounding/bonding of the Generac Generator per manufacturer’s requirements and NEC 250.

250.31(A) Grounding electrode system and grounding electrode conductor. Required.
250.31(B) equipment grounding conductor, grounding bonding equipment and structural metal. Sized accordance with 250.122.
08/11/2026 Commercial Mechanical Standard REQUIRES RESUBMIT ACTIVITY NO. TC-COM-0525-01035
ADDRESS/PARCEL: 6444 S FONTANA AV TUCSON, AZ 85706

Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review.

If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov.

COMMENTS:

1. Please provide a complete propane fuel system layout on the plans. Show the locations of the propane tanks and gas piping on the site plan, including the piping route, pipe sizes, and pipe material. Provide the total gas load for the system and identify the locations of all propane shutoff valves and regulators. Provide dimensions verifying the minimum separation distances for the propane tanks. Reference: Section 402.2, IFGC 2024 & Section 6104.3, IFC 2024.
08/04/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TC-COM-0525-01035 (3rd Review)
Project: The proposed development consists of hybrid self-storage facility with 308 modular storage units placed above grade. Site improvements will include grading and access drives.
Location: 6444 S FONTANA AV
Review Date: 8/4/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Reviewer Contact: Marco.contreras@tucsonaz.gov
Related cases:

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed to ensure final approval from Site Engineering.
To help speed up your resubmittal and facilitate shorter review timelines, please include a response letter along with your updated plans and any supporting calculations. In your response letter, address each comment individually and explain what changes were made and where they can be found in the plans. Please do not mark or highlight changes in the drawings at this stage — revision markups are only used after a permit has been issued. Submit your response letter and updated plan set as two separate files.
Site Engineering Review Comments:
1. Building plans, including the site design, must match what was approved in Development Package (Site Plan) TD-DEV-0525-00143. On review of sheets 5–7, the site plan referenced in the electrical plans does not match the approved site design. Revise the plans to carry the same dimensions shown in the approved plans. Alternatively, the approved site plan sheet may be incorporated directly into the building plan set rather than creating a separate, non-approved site plan. The response regarding site zoning is acknowledged; however, this does not resolve the discrepancy, particularly since the plans are explicitly marked "For Construction."
08/04/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0525-01035 - TD-DEV-0525-00143
6444 S. Fontana Ave. Tucson, AZ 85706
Hybrid Self Storage Facility (2nd Review)

TRANSMITTAL DATE: 8/4/2026

The site is located in C-2 zone (UDC 4.7.21).

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: Follow up to previous comment 2: Building plans including the site plan must match what was approved in the associated Development Package (TD-DEV-0525-00143). Sheets 4-10 on the building plans marked “Issued For Construction” have PAAL widths that are smaller than what was approved in the associated Development Package. Per UDC Table 7.4.6-2, PAAL’s within a storage use development must be a minimum of 30’.
2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
07/22/2026 PDSD Application Completeness Express REVIEW COMPLETED