Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2
Permit Number - TC-COM-0524-01029
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/22/2024 | Commercial Plumbing | REQUIRES RESUBMIT | Comment not addressed. Provide the water demand that the relocated 1” water meter will be serving. [Initial comment: Provide the water demand that the relocated 1” water meter will be serving. The submitted information states that the water service pipe will be 1” PEX which can accommodate a maximum demand of 15 GPM at a water velocity of 8 feet per second. Tucson Water allows a 1” water meter to serve a maximum demand of 50 GPM. Reference Section 107.2.1, IBC 2018.] | ||
| 07/03/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |