Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0524-01029
Parcel: 112043510

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.2

Permit Number - TC-COM-0524-01029
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/22/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
07/22/2024 Commercial Plumbing REQUIRES RESUBMIT Comment not addressed. Provide the water demand that the relocated 1” water meter will be serving. [Initial comment: Provide the water demand that the relocated 1” water meter will be serving. The submitted information states that the water service pipe will be 1” PEX which can accommodate a maximum demand of 15 GPM at a water velocity of 8 feet per second. Tucson Water allows a 1” water meter to serve a maximum demand of 50 GPM. Reference Section 107.2.1, IBC 2018.]
07/03/2024 PDSD Application Completeness Express REVIEW COMPLETED