Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0524-01028
Parcel: 112043510

Review Status: Requires Resubmit

Review Details: COMMERCIAL PDSD SIMPLE REVIEW v.1

Permit Number - TC-COM-0524-01028
Review Name: COMMERCIAL PDSD SIMPLE REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/17/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/17/2024 Commercial Plumbing REQUIRES RESUBMIT Provide the water demand that the relocated 1” water meter will be serving. The submitted information states that the water service pipe will be 1” PEX which can accommodate a maximum demand of 15 GPM at a water velocity of 8 feet per second. Tucson Water allows a 1” water meter to serve a maximum demand of 50 GPM. Reference Section 107.2.1, IBC 2018.
05/29/2024 PDSD Application Completeness Express REVIEW COMPLETED