Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL FENCE/WALL v.1
Permit Number - TC-COM-0524-00905
Review Name: COMMERCIAL FENCE/WALL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/04/2024 | Commercial Building | REQUIRES RESUBMIT | Automatic Entry Gate with Keypad Please submit your revised documents along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. 1. Please amend the plan to provide an elevation drawing of the accessible gate, to include 10” kick plates with any cavities created by such kickplates capped. Additionally, show latches and locks with mounting heights indicated. IBC 107.2.1 2. Provide an electrical plan to provide additional information for the house panel on Building 3 and gate operator used for this project. IBC 107.2.1 A. Amend the plans to show the location of building 3 and the house pane and show the underground electrical run from the house panel to the gate operator. IBC 107.2.1 B. Provide electrical load calculations for the house panel used for this project to ensure the panel will not be overloaded. NEC 220.40 C. Specify the type and size of conduit and conductors used in this project. IBC 107.2.1 D. Indicate the methos of bonding the gate operator to the metal fence support posts. NEC 250.194 3. Provide the manufacturers cut sheet and specifications for the gate operator. IBC 107.2.1 Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 05/30/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review PROJECT: TC-COM-0524-00905 4267 N 4TH AV. – R-2 Automatic Entry Gate with Keypad - Multifamily( 2nd Review) TRANSMITTAL: May 30, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the R-2 zone (UDC 4.7.9). A multifamily is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.6, .9, & .10. 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of the Checklist for Minor Changes to Commercial/Industrial Sites is required to be submitted and approved. The DP is a separate submittal from the building plans. The checklist can be found at: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/minor_changes_to_commercial_industrial_sites_.pdf. 2. Until a DP is submitted and approved Zoning cannot approve the DP. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/16/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |