Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0524-00875
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/20/2024 | Site Zoning | APPROVED | |||
| 05/21/2024 | Water - PDSD | APPROVED | |||
| 05/20/2024 | Site Engineering | NOT REQUIRED | |||
| 05/21/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/15/2024 | External Reviewers - Willdan | REQUIRES RESUBMIT | Contact Bill McClellan by email at bmcclellan@willdan.com or cell (928)580-3179 for review comment questions 1. Sheet A0.00 Provide complete building data for existing total square footage of building, existing occupancies, occupant loads, existing exits and existing plumbing fixtures for entire building on plans, not identified per 2018 IBC 107.2.1 (BM) , note exits are being eliminated from this remodeled space. 2. Sheet A0.04 Plumbing fixture schedule, service sink is required per 2018 IBC table 2902.1, clarify existing location or provide if not existing (BM) 3. Sheet A0.04 Plumbing fixture schedule, provide total number of existing restroom fixtures and drinking fountains to comply with occupancy requirements for total occupant load of building to comply with 2018 IBC table 2902.1, not identified on plans. (BM) 4. Sheet A6.01 Provide note in door schedule that sliding door s #6 - #10 will need to maintains minimum 32" clear width when fully open per 2010 ADA standard Figure 404.2.3 (BM) 5. Sheet M1.02 Provide duct sizes for key notes #3 & #4 for review to verify with new ducting sizes and connections, not identified on plans per 2018 IMC 106.3.1 (BM) 6. Sheet M2.01 Provide equipment schedule for existing equipment to identify all electrical & gas supply data, supply and return air CFM provided, OSA minimum requirements for review to verify with information provided M1.02 per 2018 IMC 106.3.1 (BM) 7. Sheet M3.01 Provide mechanical compliance certificate as noted above in IECC compliance note section and per 2018 IECC C403 (BM) 8. Sheet E4.01 Exit signs identified on new egress plans should be identified on electrical lighting plan to match tenant space requirements. 2018 IBC 107.2.1 (BM) 9. Sheet E5.01 Maintenance receptacle is required at new DCU/1 location per 2017 NEC 210.63 (BM) |
||
| 05/13/2024 | Fire New Construction | REVIEW COMPLETED | |||
| 05/07/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |